info@ledluxhub.com+8615397378162
Home     Products     MEAN WELL     Medical Grade Power Supplies       MEAN WELL Power Supply GST160A Series Re
  • MEAN WELL Power Supply GST160A Series Reliable Green Industrial Adaptor - Image 1

MEAN WELL Power Supply GST160A Series Reliable Green Industrial Adaptor

  • Product Item : GST160A series
  • Category:Medical Grade Power Supplies
  • Wattage: 160W
  • Input Voltage: 85 ~ 264VAC or 120-370VDC
  • Current Range: 3.34 ~ 11.5A
  • DC Voltage: 12 ~ 48V
  • Product description:GST160A is a highly reliable, 160W desktop style single-output green adaptor series.
  • INQUIRY   EMAIL

GST160A Series - 160W Desktop Adapter with Active PFC, Class I, 3-Pole IEC320-C14 Inlet, 6 Output Models 12V ~ 48VDC, Level VI

175 x 72 x 35mm | 85~264VAC / 120~370VDC Input | 6 Output Models 12V ~ 48VDC | 138W~160W | 3-Pole IEC320-C14 AC Inlet | Class I with Protective Earth | Active PFC, PF>0.98 | No-Load <0.15W | Efficiency Level VI, up to 94% | Leakage 0.75mA Max | -30~+70C | 3-Year Warranty

In Stock 3-Year Warranty Efficiency Level VI Class I IEC320-C14 Inlet Active PFC EMC Class B 160W Max

Key Performance at a Glance

160W
Rated Power
94%
Peak Efficiency
6
Output Voltages
<0.15W
No-Load Power
Class I
Protection Class
C14
AC Inlet

Product Overview

The MEAN WELL GST160A series is a high-reliability 160W AC-DC desktop single-output green adapter built into a fully enclosed plastic housing. It connects to mains through a 3-pole IEC320-C14 inlet and is a Class I power supply with protective earth. Input range is 85~264VAC or 120~370VDC, and the series covers six output voltages from 12V to 48VDC - adding a 36V model to the usual 12V / 15V / 20V / 24V / 48V line-up - serving consumer electronic devices, telecom equipment, office equipment and industrial equipment.

The input stage uses active power factor correction: power factor is above 0.93 at 230VAC on the 12V and 15V models, above 0.94 from 20V upwards, and above 0.98 at 115VAC at full load. Maximum leakage current is only 0.75mA at 240VAC despite the higher output power. Withstand voltage is 3KVAC input-to-output, 2KVAC input-to-FG with the output-to-FG path effectively shorted, and insulation resistance is 100M Ohms minimum at 500VDC. The 94V-0 flame-retardant enclosure is fully sealed, so no live part is exposed in normal operation. This is an ITE product: for patient-contact medical equipment choose a 60601-1 certified adapter from the GSM series instead.

Typical efficiency runs from 90% on the 12V model to 94% on the 48V model, with no-load power consumption below 0.15W across the whole series, meeting Efficiency Level VI and complying with USA EISA 2007/DoE, Canada NRCan, Korea K-MEPS, AU/NZ MEPS, EU ErP and CoC Version 5. Efficiency is published per model and is not strictly proportional to output voltage: the 36V model is rated 92%, slightly below the 24V model's 93%, and that is the datasheet figure rather than a rounding artefact. Safety approvals cover UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, IEC62368-1, BSMI CNS15598-1, CCC GB4943.1, PSE J62368-1, AS/NZS 62368.1, BIS IS13252, KC K60950-1 and EAC TP TC 004, with conducted and radiated emissions held to Class B limits.

The standard output plug on all six models is the R7B 4-pin power DIN with lock, and on the R7B the negative output is connected to AC FG, so the output is referenced to protective earth rather than floating. Tuning fork, DIN, XLR, MOLEX and AMP connectors can be fitted at the factory, and a quick-change plug adapter is offered for the P1J and P1M tuning-fork plugs - rated 24~48V / 7.5A maximum, which rules out the 12V (11.5A), 15V (9.6A) and 20V (8A) models. Protections cover short circuit, overload (105%~150% of rated power, hiccup mode with auto-recovery), over voltage (105%~135% of rated output voltage, hiccup mode at 10% load) and over temperature (shutdown, restart after cooling). The 175 x 72 x 35mm adapter weighs 660g, operates from -30C to +70C and is backed by a 3-year warranty.

Product Images

GST160A series 160W desktop adapter with active PFC and IEC320-C14 inlet product image
GST160A series standard R7B 4-pin power DIN DC output plug
GST160A series desktop adapter 175 x 72 x 35mm dimension drawing

Technical Specifications

Output ratings for all six GST160A models. All values measured at 230VAC input, rated load, 25C / 70%RH unless otherwise noted.

Model Output Voltage Rated Current Current Range Rated Power (Max) Efficiency (Typ.)
GST160A12-R7B 12V 11.5A 0 ~ 11.5A 138W 90%
GST160A15-R7B 15V 9.6A 0 ~ 9.6A 144W 91%
GST160A20-R7B 20V 8A 0 ~ 8A 160W 93%
GST160A24-R7B 24V 6.67A 0 ~ 6.67A 160W 93%
GST160A36-R7B 36V 4.44A 0 ~ 4.44A 160W 92%
GST160A48-R7B 48V 3.34A 0 ~ 3.34A 160W 94%

Efficiency is published as one figure per model, because the standard R7B plug is the only build listed for this series. It does not rise monotonically with voltage: 36V is specified at 92%, below the 24V model's 93%. Models are 12V 138W, 15V 144W and 160W for 20V / 24V / 36V / 48V - current is capped by the 160W platform, so the lower voltages do not reach the full 160W.

Model Ripple & Noise (Max) Voltage Tolerance Line Regulation Load Regulation
GST160A12-R7B 80mVp-p ±5.0% ±1.0% ±5.0%
GST160A15-R7B 100mVp-p ±5.0% ±1.0% ±5.0%
GST160A20-R7B 120mVp-p ±4.0% ±1.0% ±4.0%
GST160A24-R7B 150mVp-p ±3.0% ±1.0% ±3.0%
GST160A36-R7B 150mVp-p ±3.0% ±1.0% ±3.0%
GST160A48-R7B 200mVp-p ±3.0% ±1.0% ±3.0%

Overload and over-voltage protection are specified once for the whole series rather than per model: overload trips at 105%~150% of rated output power in hiccup mode with automatic recovery, and over-voltage trips at 105%~135% of rated output voltage in hiccup mode at 10% load. Both are listed in full in the Input & Protection table below.

DC Plug & Connector Options

Style Type Model OD x ID x L (mm) Quick-Change Adapter
Standard (all models) 4-pin power DIN with lock, -V bonded to AC FG R7B - Supplied on all six models
Tuning Fork Straight (5.5 x 2.1 x 11.0) P1J 5.5 x 2.1 x 11.0 P1J / P1M only (24~48V, 7.5A max)
Tuning Fork Straight (5.5 x 2.5 x 11.0) P1M 5.5 x 2.5 x 11.0 P1J / P1M only (24~48V, 7.5A max)
Min. DIN 4 Pin with Lock (female) KYCON KPJX-CM-4S equivalent R7BF - Not available
DIN 5 Pin (male) - R1B - Not available
XLR 4 Pin (NEUTRIK NC4FX equivalent) - MIC4 - Not available
MOLEX 39-01-2060 (4.2mm) equivalent FG not connected to the output connector C6P - Not available
AMP 1-480702-0 (6.35mm) equivalent FG not connected to the output connector C4P - Not available
Stripped & tinned leads Custom (MOQ required) Custom Red / blue +Vo, black / white -Vo | standard L: 25mm, L1: 5mm Not available

Note: quick-change adapter availability is listed per plug family as published in the MEAN WELL datasheet. On the GST160A only the P1J and P1M tuning-fork plugs accept a quick-change adapter, and only from 24V to 48V at 7.5A maximum - the 12V model delivers 11.5A, the 15V model 9.6A and the 20V model 8A, all above that limit, so those three run on their factory-fitted plug only. Every other style is factory-fit and requires a minimum order quantity. On the standard R7B plug the negative output is connected to AC FG; the optional C6P and C4P connectors leave FG unconnected to the output connector, so confirm your grounding scheme when ordering. Wire colours on stripped-lead versions are for reference only.

Input & Protection (All Models)

AC Input Range 85~264VAC | 47~63Hz
DC Input Range 120~370VDC
AC Inlet 3-pole IEC320-C14 inlet | Class I construction with protective earth
Power Factor (Typ.) PF>0.93 on 12V / 15V, PF>0.94 from 20V up / 230VAC | PF>0.98 / 115VAC at full load | Active PFC
AC Current (Typ.) 1.85A / 115VAC | 1A / 230VAC
Inrush Current (Max.) Cold start 95A / 115VAC | 120A / 230VAC
Leakage Current (Max.) 0.75mA / 240VAC
Efficiency (Typ.) 90% / 91% / 93% / 93% / 92% / 94% on 12V / 15V / 20V / 24V / 36V / 48V | Efficiency Level VI for the whole series | Complies with USA EISA 2007/DoE, Canada NRCan, Korea K-MEPS, AU/NZ MEPS, EU ErP and CoC Version 5
No-Load Power Consumption <0.15W
Set Up / Rise Time 2000ms, 50ms / 230VAC | 2500ms, 50ms / 115VAC at full load
Hold Up Time (Typ.) 20ms / 230VAC | 20ms / 115VAC at full load
Overload Protection 105%~150% of rated output power | Hiccup mode, auto-recovery after the fault condition is removed
Over-Voltage Protection 105%~135% of rated output voltage | Hiccup mode at 10% load
Over-Temperature Protection Output shutdown, restart to recover after the unit cools down
Operating Temp / Humidity -30~+70C (refer to derating curve) | 20~90% RH non-condensing
Storage Temp / Humidity -40~+85C | 10~95% RH non-condensing
Temp Coefficient ±0.03%/C (0~50C)
Vibration 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis
DC Output Cable UL2464 16AWG x 4C 1000±50mm on 12V | UL2464 18AWG x 4C 1200±50mm on 15~48V
Output Reference (-V / FG) Standard R7B plug: -V is connected to AC FG, so the output is referenced to protective earth | Optional C6P / C4P connectors: FG not connected to the output connector
MTBF 2205.4K hrs min. Telcordia SR-332 (Bellcore) | 236.4K hrs min. MIL-HDBK-217F (25C)
Dimensions / Packing 175 x 72 x 35mm (L*W*H) | 0.66Kg; 20pcs / 14.2Kg / 0.95CUFT per carton
Enclosure Model / Indicator Enclosure model GS160A | Power-on LED indicator on the housing

Safety Standards & Certifications

ITE Safety Standards UL62368-1; CSA C22.2 No.62368-1; TUV BS EN/EN62368-1; IEC62368-1; BSMI CNS15598-1; CCC GB4943.1; PSE J62368-1; AS/NZS 62368.1; BIS IS13252; KC K60950-1; EAC TP TC 004
Protection Class Class I (protective earth bonded through the 3-pole IEC320-C14 inlet)
Withstand Voltage I/P-O/P: 3KVAC | I/P-FG: 2KVAC | O/P-FG: SHORT
Insulation Resistance I/P-O/P: 100M Ohms / 500VDC / 25C / 70% RH
EMC Emission Conducted emission: BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B), CNS15936, GB17625.1, EAC TP TC 020, MSIP KN32 - Class B | Radiated emission: same standards, Class B | Harmonic current: BS EN/EN61000-3-2, GB9254 Class A | Voltage flicker: BS EN/EN61000-3-3
EMC Immunity BS EN/EN55035 | ESD BS EN/EN61000-4-2 Level 4 (15KV air) / Level 4 (8KV contact) | RF field BS EN/EN61000-4-3 Level 2, 3V/m | EFT bursts BS EN/EN61000-4-4 Level 3, 2KV | Surge BS EN/EN61000-4-5 Level 3, 1KV line-line / 2KV line-FG | Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V | Magnetic field BS EN/EN61000-4-8 Level 2, 3A/m | Voltage dips and interruption BS EN/EN61000-4-11
Housing / Protections 94V-0 flame-retardant fully enclosed plastic housing | Protections: short circuit / overload / over voltage / over temperature
Warranty 3 years

Key Features

160W Across Six Voltages
One 160W desktop platform covers 12V / 15V / 20V / 24V / 36V / 48VDC. The 12V model is rated 138W and the 15V model 144W; 20V, 24V, 36V and 48V deliver the full 160W. The 36V model is the addition to this platform, and there are still no 5V, 7.5V, 9V, 18V or 28V versions.
Active PFC, PF Above 0.94
Power factor is above 0.93 at 230VAC on 12V / 15V and above 0.94 from 20V up, reaching above 0.98 at 115VAC at full load. The active PFC front end keeps input current and harmonic current low and holds leakage current to 0.75mA at 240VAC, which matters when several adapters share one distribution board.
Class I with 3-Pole IEC320-C14 Inlet
The GST160A connects through a standard 3-pole IEC320-C14 mains inlet and bonds the protective earth, so it suits installations that require a grounded chassis. Withstand voltage is 3KVAC input-to-output and 2KVAC input-to-FG, with 100M Ohms minimum insulation resistance.
AC and DC Input
Besides the 85~264VAC universal input, the series accepts 120~370VDC on the same terminals, so it can run from a DC bus without an extra conversion stage. Inrush current is 95A at 115VAC and 120A at 230VAC cold start, so check the upstream breaker rating.
Level VI Efficiency, No-Load Below 0.15W
Typical efficiency from 90% to 94% across the six models with no-load power below 0.15W. The whole series meets Efficiency Level VI and complies with USA EISA 2007/DoE, Canada NRCan, Korea K-MEPS, AU/NZ MEPS, EU ErP and CoC Version 5.
Earth-Referenced Output, Strong EFT Immunity
The standard R7B plug bonds the negative output to AC FG, so the output is earth-referenced rather than floating. EFT immunity is Level 3 at 2KV and ESD Level 4 at 15KV air / 8KV contact. 94V-0 flame-retardant enclosure, power-on LED, 175 x 72 x 35mm, 0.66Kg, -30C to +70C, 3-year warranty.

Frequently Asked Questions

Which safety standards and certifications does the GST160A series carry?

GST160A is certified to UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, IEC62368-1, BSMI CNS15598-1, CCC GB4943.1, PSE J62368-1, AS/NZS 62368.1, BIS IS13252, KC K60950-1 and EAC TP TC 004. Conducted and radiated emissions meet Class B limits to BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B), CNS15936, GB17625.1, EAC TP TC 020 and MSIP KN32. ESD immunity is Level 4 at 15KV air and Level 4 at 8KV contact, and EFT immunity is Level 3 at 2KV.

Is the DC output of the GST160A floating or earth-referenced?

Earth-referenced, on the standard build. The datasheet R7B pin definition states that the negative output (-V) is connected to AC FG, so the output sits on protective earth through the mains inlet - this is not an isolated floating output. If your end device expects a floating output, or if the load side already has its own earth reference, tell us before ordering: the optional C6P and C4P connectors are specified with FG not connected to the output connector, and a modified build can be discussed with a minimum order quantity.

Is the GST160A really 160W on every output voltage?

No. The 12V model is rated 138W (11.5A) and the 15V model 144W (9.6A). The 20V, 24V, 36V and 48V models deliver the full 160W. All six share the same 175 x 72 x 35mm housing and the same 85~264VAC / 120~370VDC input range. The series starts at 12V: there is no 5V, 7.5V, 9V, 18V or 28V model, so if you need a voltage below 12V choose GST40A or GST60A instead.

Why is the 36V model less efficient than the 24V model?

Because that is the published figure. The GST160A datasheet specifies 93% for both the 20V and 24V models, 92% for the 36V model and 94% for the 48V model. Efficiency on this platform is not a straight line with output voltage, and 36V is the model where the switching and transformer design sits least favourably. Quote 92% for GST160A36-R7B - do not carry the 24V or 48V number across, and do not use the series headline of 94% when the end customer is comparing a 36V design.

What DC plug comes with the GST160A, and can I order a different one?

The standard plug on all six models is R7B, a 4-pin power DIN with lock and centre positive. Tuning fork (P1J, P1M), DIN 4-pin female (R7BF), DIN 5-pin (R1B), XLR (MIC4), MOLEX 39-01-2060 (C6P) and AMP 1-480702-0 (C4P) can be fitted at the factory subject to a minimum order quantity. For small quantities a quick-change DC plug adapter is available for the P1J and P1M tuning-fork plugs, rated 24~48V at 7.5A maximum.

Can I use a quick-change plug adapter on the 12V, 15V or 20V model?

No. The quick-change adapter is rated 7.5A maximum and 24~48V, while the 12V model delivers 11.5A, the 15V model 9.6A and the 20V model 8A. Only the 24V (6.67A), 36V (4.44A) and 48V (3.34A) models are within the limit. On the three lower-voltage models the plug is factory-fitted and cannot be swapped in the field.

Is the GST160A a Class I or a Class II power supply?

GST160A is a Class I power supply. It connects through a 3-pole IEC320-C14 inlet and bonds the protective earth, which is why the mains side carries a protective earth conductor, and it uses a 94V-0 flame-retardant fully enclosed plastic housing. It is not a double-insulated Class II product and must be run from an earthed mains supply.

How do the protection circuits of the GST160A behave?

Overload protection trips at 105%~150% of rated output power and runs in hiccup mode, recovering automatically once the fault is removed. Over-voltage protection trips at 105%~135% of rated output voltage and is also specified as hiccup mode at 10% load. Over-temperature protection shuts the output down and requires a restart after the unit has cooled. Short circuit protection recovers automatically.

How does the GST160A differ from the GST120A?

GST160A is the next platform up: 160W instead of 120W, six voltage models instead of five because a 36V version is added, and a larger housing at 175 x 72 x 35mm / 660g against 167 x 67 x 35mm / 575g, so it is not a drop-in mechanical swap. Input current rises to 1.85A at 115VAC, inrush to 95A / 120A, EFT immunity to Level 3 at 2KV, and the over-voltage protection now recovers in hiccup mode rather than latching off. Gain on the other side is a 94% peak efficiency model and I/P-FG withstand voltage of 2KVAC.

Can I use the GST160A for a medical device?

No. GST160A is an ITE product certified to the 62368-1 safety standard. For equipment with patient contact, use a 60601-1 certified adapter from the MEAN WELL GSM medical series instead, which provides 2xMOPP isolation and touch current below 50uA. The adapter is in any case a component intended to be built into end equipment, so EMC and safety of the complete system must be confirmed with the finished device.

Related Products

Explore every output voltage in the GST160A family.

Available Models

  • GST160A12-R7B - 12VDC / 11.5A (138W max) / ripple <80mVp-p / ±5.0% accuracy / 90% efficiency / Level VI / R7B standard plug only; no quick-change adapter
  • GST160A15-R7B - 15VDC / 9.6A (144W max) / ripple <100mVp-p / ±5.0% accuracy / 91% efficiency / Level VI / R7B standard plug only; no quick-change adapter
  • GST160A20-R7B - 20VDC / 8A (160W max) / ripple <120mVp-p / ±4.0% accuracy / 93% efficiency / Level VI / R7B standard plug only; no quick-change adapter
  • GST160A24-R7B - 24VDC / 6.67A (160W max) / ripple <150mVp-p / ±3.0% accuracy / 93% efficiency / Level VI / R7B standard plug; quick-change P1J / P1M supported
  • GST160A36-R7B - 36VDC / 4.44A (160W max) / ripple <150mVp-p / ±3.0% accuracy / 92% efficiency / Level VI / R7B standard plug; quick-change P1J / P1M supported
  • GST160A48-R7B - 48VDC / 3.34A (160W max) / ripple <200mVp-p / ±3.0% accuracy / 94% efficiency / Level VI / R7B standard plug; quick-change P1J / P1M supported

INQUIRY US

CATEGORIES

CONTACT US

Mobile:+8615397378162

Tel:+86-577-89887719

Whatsapp:+8615397378162

Email:info@ledluxhub.com

Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA