219 x 63 x 35.5mm Metal Housing | 100~305VAC Universal Input (142~431VDC) | L-Type 700mA / M-Type 1400mA / H-Type 4900mA | Constant Power 240W | Optional 12V/250mA Aux Output (DA2-A) | Active PFC | Type HL | IP67 | DALI-2 DT6 | >50,000hrs | 5-Year Warranty
The MEAN WELL XLG-240-DA2 series is a 240W AC-to-DC constant-power LED driver family with DALI-2 digital dimming, IP67 protection, and Type HL certification for Class I, Division 2 hazardous location lighting. It is designed for LED street lighting, flood lighting, stage lighting, fishing lighting, horticultural lighting, bay lighting, and industrial lighting.
It accepts universal 100~305VAC input (142~431VDC) and provides a constant-power 240W output. Three output types are available: L-Type with default current 700mA and CC region 178~342V, M-Type with default current 1400mA and CC region 90~171V, and H-Type with default current 4900mA and CC region 27~56V. Output current can be adjusted via an internal potentiometer (350~1050mA for L-Type, 700~2100mA for M-Type, 2400~6660mA for H-Type). With peak efficiency up to 94%, the driver uses a fanless design and operates at case temperatures from -40C to +90C under free air convection.
The metal enclosure carries an IP67 rating for both indoor and outdoor use. All DA2 versions support IEC 62386 DALI-2 DT6 digital dimming down to approximately 8% minimum brightness, with isolated dimming circuitry. A DA2-A option adds a galvanically isolated 12V/250mA auxiliary output to power a DALI controller, sensor or communication module. India versions (XLG-240I-*-DA2) add input over-voltage protection at 320~390VAC and comply with IS 15885. No-load / standby power consumption of the standard DA2 versions is below 0.5W.
Protection includes short-circuit (hiccup or constant current limiting, auto-recovery) and over-temperature (de-rate to 75% then 50%, auto-recovery). Input over-voltage protection (320~390VAC, auto-recovery; withstands 440VAC for 48h) is available on I-Type only. The driver complies with global lighting safety and EMC standards including UL8750 Type HL, CSA, ENEC (with emergency-lighting EL appendix J, DC input 176~280Vdc), AS/NZS, BS EN/EN, GB/T, EAC, and IS 15885 (I-Type only), and is backed by a 5-year warranty. Note: a switch must be installed between the mains and the LED driver to meet the latest ErP regulations.
Output ratings for the XLG-240-DA2 series. All values measured at 230VAC, rated load, 25C unless noted.
| Model | Rated Power | Default Current | CC Region | Full Power Current | Open Circuit Max | Adjustment Range | Efficiency |
|---|---|---|---|---|---|---|---|
| XLG-240-L-DA2 | 239.4W | 700mA | 178 ~ 342V | 700~1050mA | 380V | 350~1050mA | 94% |
| XLG-240-M-DA2 | 239.4W | 1400mA | 90 ~ 171V | 1400~2100mA | 197V | 700~2100mA | 93.5% |
| XLG-240-H-DA2 | 239.6W | 4900mA | 27 ~ 56V | 4280~6660mA | 65V | 2400~6660mA | 93% |
| Type | IP | Output Adjustment | Dimming / Aux | Input OVP | Notes |
|---|---|---|---|---|---|
| L-DA2 | IP67 | 350~1050mA via built-in potentiometer | DALI-2 DT6 (isolated, down to ~8%) | No | 239.4W / 178~342V / 700mA default; Type HL |
| M-DA2 | IP67 | 700~2100mA via built-in potentiometer | DALI-2 DT6 (isolated, down to ~8%) | No | 239.4W / 90~171V / 1400mA default; Type HL |
| H-DA2 | IP67 | 2400~6660mA via built-in potentiometer | DALI-2 DT6 (isolated, down to ~8%) | No | 239.6W / 27~56V / 4900mA default; Type HL |
| DA2-A (option) | IP67 | Same as base type | DALI-2 DT6 + isolated 12V@250mA aux output | No | Custom; aux feeds DALI controller / sensor; whole-unit efficiency -1% at 3W aux load |
| I-L / I-M / I-H -DA2 | IP67 | Same as non-I versions | Same as non-I versions | Yes (320~390VAC) | India version (EESL); withstand 440VAC for 48h; IS 15885; no UL/CSA |
| Input Voltage Range | 100~305VAC | 142~431VDC | 47~63Hz |
| Active PFC / THD / AC Current | PF>=0.97/115V, >=0.95/230V, >=0.92/277V at full load | THD<10% (@load>=50%/115VAC,230VAC; @load>=75%/277VAC) | 2.7A/115V, 1.3A/230V, 1.1A/277VAC |
| Inrush / Leakage / Breaker | Cold start 85A (twidth=500us measured at 50% Ipeak) / 230VAC per NEMA 410 | 16A breaker: 2 units (B type) / 4 units (C type) at 230VAC | <0.75mA/277VAC |
| Set Up / Rise Time | 500ms / 230VAC; 1200ms / 115VAC (DALI-2 startup timing tested with DALI controller supporting power-on function) |
| No-Load / Standby Power | <0.5W on standard DA2 versions (dimming off) |
| Aux Output (DA2-A) | 12V @ 250mA, accuracy ±10%, ripple 200mVp-p, isolated |
| Protection | Short circuit: hiccup or constant current limiting, auto-recovery | Over temp: state 1 de-rate to 75%, state 2 de-rate to 50%, auto-recovery | Input OVP: 320~390VAC on I-Type only, auto-recovery; withstand 440VAC for 48h |
| Current Ripple / Tolerance | <5.0% @ rated current | Current accuracy ±5% |
| Operating / Storage Temp | Tcase=-40C to +90C (refer to derating curve) | Storage -40C~+80C | Temp coefficient ±0.06%/C (0~60C) |
| Vibration / Humidity | 10~500Hz, 5G, 12min/cycle, X/Y/Z 72min each | 20~95% RH non-condensing |
| Isolation | 3.75KVac I/P-O/P, 2KVac I/P-FG, 1.8KVac O/P-FG |
| EMC Emission / Immunity | EN55015/CISPR15, GB/T17743; Harmonic Class C (@load>=50%); EN61000-3-3 | Immunity: EN61000-4-2 Level 3, EN61000-4-3 Level 2, EN61000-4-4 Level 3, EN61000-4-5 (6KV line-earth / 4KV line-line), EN61000-4-6 Level 2, EN61000-4-8 Level 4, EN61000-4-11, EN61547 |
| Lifetime / MTBF / Size | >50,000 hours at Tcase<75C | 1998.7K hrs (Telcordia SR-332) / 170.5K hrs (MIL-HDBK-217F, 25C) | 219 x 63 x 35.5mm | 1Kg; 16pcs/16Kg/0.80CUFT |
| Safety Standards | UL8750 (Type HL), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency lighting (DC input 176~280Vdc), BS EN/EN62384, GB/T19510.1, GB/T19510.213, EAC TP TC 004, IS 15885 (Part 2/Sec13) for I-Type only | IP67 |
| DALI Standard | IEC 62386-101, 102, 207, 251; Device Type 6 (DT6) |
| Withstand Voltage | I/P-O/P: 3.75KVAC | I/P-FG: 2.0KVAC | O/P-FG: 1.8KVAC |
| Insulation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25C / 70% RH |
| EMC Emissions | BS EN/EN55015 (CISPR15), GB/T17743; Harmonic BS EN/EN61000-3-2 Class C (@load>=50%); BS EN/EN61000-3-3 |
| EMC Immunity | BS EN/EN61547, BS EN/EN61000-4-2 Level 3 (8KV air / 4KV contact), BS EN/EN61000-4-3 Level 2, BS EN/EN61000-4-4 Level 3, BS EN/EN61000-4-5 (6KV line-earth / 4KV line-line), BS EN/EN61000-4-6 Level 2, BS EN/EN61000-4-8 Level 4, BS EN/EN61000-4-11 |
L-Type is for high-voltage LED strings (default 700mA, CC region 178~342V), M-Type for mid-voltage loads (default 1400mA, CC region 90~171V), and H-Type for low-voltage high-current loads (default 4900mA, CC region 27~56V). All three deliver approximately 240W constant power and support DALI-2 DT6 dimming.
Yes, all DA2 versions comply with IEC 62386-101, 102, 207, 251 and support Device Type 6 (DT6) DALI-2 digital dimming. The dimming circuit is isolated from the output. Minimum dimming level is approximately 8%.
DA2-A is a custom option that adds an isolated 12V/250mA auxiliary output (accuracy ±10%, ripple 200mVp-p) to power a DALI controller, sensor or communication module. When the aux output carries its full 3W load, whole-unit efficiency drops by about 1%.
Standard L/M/H-DA2 are global versions. XLG-240I-*-DA2 are India-market versions (EESL) that add input over-voltage protection (320~390VAC), withstand 440VAC for 48 hours, and carry IS 15885 certification. I-Type versions have no UL/CSA marks.
XLG-240-DA2 is a constant-power LED driver that operates in constant-current mode within the stated CC region; it is not a constant-voltage supply. Type HL means the driver is UL8750 listed for use in Class I, Division 2 hazardous location lighting fixtures when installed per manufacturer instructions (consider built-in installation).
Explore individual models in the XLG-240-DA2 family.
Mobile:+8615397378162
Tel:+86-577-89887719
Whatsapp:+8615397378162
Email:info@ledluxhub.com
Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA