info@ledluxhub.com+8615397378162
Home     Products     MEAN WELL     DIN Rail Power Supplies       MEAN WELL Power Supply XDR-960E Series S
  • MEAN WELL Power Supply XDR-960E Series Single Output DIN Rail Mounted - 副本

MEAN WELL Power Supply XDR-960E Series Single Output DIN Rail Mounted - 副本

  • Product Item : XDR-960E series
  • Category:DIN Rail Power Supplies
  • Wattage: 960W
  • Input Voltage: 180 ~ 264VAC
  • Output Current: 0 ~ 40A
  • Output Voltage: 24 ~ 48V
  • Product description:The XDR-960E series is a 960W AC/DC economical ultra slim industrial DIN rail power.
  • INQUIRY   EMAIL

SDR-75 Series - 75W DIN Rail Power Supply with 150% Peak Power

32mm Slim | 88-264Vac Input | 150% Peak (112.5W/3s) | Up to 90% Efficiency | 80ms Hold-up | UL508 | SEMI F47 | Class B EMC | -30~70C | 3-Year Warranty

✓ In Stock 3-Year Warranty 150% Peak Power UL508 Listed SEMI F47 80ms Hold-up

Key Performance at a Glance

75W
Rated Power
112.5W
Peak Power (3s)
80ms
Hold-up (230Vac)
32mm
Width (Slim)
90%
Max Efficiency
-30~70C
Operating Temp Range

Product Overview

The SDR-75 series is a rugged 75W DIN rail power supply purpose-built for industrial control equipment with UL508 listing and SEMI F47 voltage sag immunity. Its standout feature is 150% peak power (112.5W for 3 seconds) — ideal for starting motors, contactors, and capacitive loads that demand momentary high current.

The SDR-75 accepts 88~264Vac universal input (also 124~370Vdc). Available in three output voltages - 12V, 24V, and 48V - it delivers up to 6.3A at 12V and 1.6A at 48V. Efficiency ranges from 88.5% to 90%. An exceptional 80ms hold-up time at 230Vac (20ms at 115Vac) provides superior brownout ride-through — among the longest in the 75W DIN rail class.

The peak power capability works in two modes: after a 100-second recovery at rated load, the unit can deliver 150% for 3 seconds; or after a 15-second recovery at 50% load, another 3-second peak burst is available. This intelligent thermal management ensures reliable peak power delivery without nuisance tripping. The overload protection is time-adaptive: 110~150% overload runs for >3 seconds before shutdown, while 150~170% uses constant current limiting for 3 seconds then shuts down — both requiring a restart.

The SDR-75 holds UL508, TUV BS EN/EN62368-1, AS/NZS 62368.1, and EAC certifications with GL design reference for marine applications. SEMI F47 certification ensures immunity to voltage sags common in semiconductor manufacturing environments. With Class B EMC emissions and EN61000-6-2 heavy industrial immunity, the SDR-75 is qualified for the most demanding industrial installations. The fanless convection-cooled design operates from -30C to +70C at up to 2,000m altitude.

Product Images

SDR-75 product image
SDR-75 product image
SDR-75 product image

Technical Specifications

Parameter SDR-75-12 SDR-75-24 SDR-75-48
DC Output Voltage12V24V48V
Rated Current6.3A3.2A1.6A
Rated Power75.6W76.8W76.8W
Peak Current (3s)9.375A4.69A2.34A
Peak Power (3s)112.5W112.5W112.5W
Ripple & Noise (max)100mVp-p100mVp-p120mVp-p
Voltage Adjustment Range12~14V24~28V48~55V
Voltage Accuracy+/-1.0%+/-1.0%+/-1.0%
Line Regulation+/-0.5%+/-0.5%+/-0.5%
Load Regulation+/-1.0%+/-1.0%+/-1.0%
Efficiency (Typ.)88.5%89%90%

Input Specifications (All Models)

Input Voltage Range88~264Vac (universal); 124~370Vdc (connect AC/L(+) and AC/N(-) for DC input)
Frequency Range47~63Hz
AC Current (Typ.)1.4A / 115Vac | 0.85A / 230Vac
Inrush Current (Typ.)30A / 115Vac | 50A / 230Vac (cold start)
Leakage Current< 1mA / 240Vac
Start-up / Rise Time1500ms/60ms @ 230Vac; 3000ms/60ms @ 115Vac (full load)
Hold-up Time (Typ.)80ms / 230Vac | 20ms / 115Vac (full load) — exceptional 80ms at 230V

Protection Features & Environmental Ratings

Overload Protection110~150%: operates >3 sec then shutdown, restart to recover | 150~170%: CC limiting for 3 sec then shutdown, restart to recover (time-adaptive dual-range)
Overvoltage Protection12V: 14~17V / 24V: 29~33V / 48V: 56~65V (shutdown output, auto-recovery after restart)
Over-temperature Protection100C +/-10C (RTH2, detects main power transistor); shutdown output, auto-recovery after temperature drops
Short Circuit ProtectionShutdown output, restart to recover
Peak Power Recovery CycleAfter 100s at rated load: 150% for 3s | After 15s at 50% load: 150% for 3s
Operating Temperature-30~+70C (refer to derating curve; note: derating required at low input voltage)
Operating Humidity20~95% RH, non-condensing
Storage Temp / Humidity-40~+85C, 10~95% RH, non-condensing
Temperature Coefficient+/-0.03%/C (0~60C)
Vibration Resistance10~500Hz, 2G, 10 min/cycle, 60 min each for X, Y, Z axes; IEC60068-2-6
AltitudeUp to 2,000m; derate ambient temp by 3.5C/1,000m above 2,000m
MTBF>= 2,670.8K hrs (Telcordia SR-332); >= 479.8K hrs (MIL-HDBK-217F, 25C)
Dimensions32 x 125.2 x 102 mm (WxHxD)
Net Weight / Packaging0.51 kg / 28 pcs per carton / 15.3 kg / 1.23 CUFT

Safety Standards & Certifications

Safety StandardsUL508 (Industrial Control Equipment) | TUV BS EN/EN62368-1 | AS/NZS 62368.1 | EAC TP TC 004
Design refers to: GL (marine) | Meets BS EN/EN60204-1 (machinery electrical safety)
SEMI F47Certified — voltage sag immunity for semiconductor manufacturing equipment
Withstand VoltageI/P-O/P: 3KVac | I/P-FG: 2KVac | O/P-FG: 0.5KVac
Insulation ResistanceI/P-O/P, I/P-FG, O/P-FG: > 100Mohm / 500Vdc / 25C / 70% RH
EMC EmissionsBS EN/EN55032 (CISPR32) / BS EN/EN61204-3 - Class B
Harmonic: BS EN/EN61000-3-2 | Flicker: BS EN/EN61000-3-3 | EAC TP TC 020
EMC ImmunityBS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3 — Heavy Industrial Level
Compliant with EN61000-4-2,3,4,5,6,8,11 | EAC TP TC 020 | SEMI F47

Key Features

150% Peak Power (112.5W/3s)
Delivers 150% rated power for 3 seconds — safely starts motors, contactors, and capacitive loads without tripping or oversizing the supply
80ms Hold-up at 230Vac
Exceptional ride-through time — among the longest in 75W DIN rail class — keeps PLC and control systems alive through extended brownouts
UL508 Industrial Control Listed
Certified to UL508 for industrial control panels — mandatory for North American machinery and process control installations
SEMI F47 Voltage Sag Immunity
Certified to withstand voltage sags per semiconductor industry standard — critical for wafer fab and test equipment power
Time-Adaptive Overload Protection
110~150%: sustained >3s operation | 150~170%: 3s CC limiting — intelligently adapts to overload severity for maximum uptime
32mm Ultra-Slim Design
One of the slimmest 75W DIN rail supplies — maximizes panel space in crowded industrial control cabinets
Heavy Industrial EMC Immunity
EN61000-6-2 (EN50082-2) heavy industrial immunity + Class B emissions — deploy in the harshest factory environments
GL Marine Design Reference
Designed with reference to GL (Germanischer Lloyd) marine standards — suitable for shipboard and offshore applications
-30C Low-Temperature Operation
Reliable startup and operation from -30C to +70C — suitable for unheated outdoor enclosures and cold storage
3-Year Warranty + 100% Burn-In
Every unit undergoes full-load burn-in testing before shipment — backed by a 3-year warranty for industrial reliability

Frequently Asked Questions

How does the 150% peak power work in practice?

The SDR-75 can deliver 112.5W for 3 seconds. Recovery depends on the previous load: after 100 seconds at rated load (75W), it can deliver another 3-second 150% burst. After 15 seconds at 50% load (37.5W), it can also deliver another burst. This makes it excellent for cyclic loads like motor starts, solenoid activation, and contactor coil inrush where peak demand is intermittent.

How does SDR-75 differ from NDR-75?

Key differences: (1) 150% peak power vs none, (2) 80ms hold-up at 230V vs 60ms, (3) UL508 + SEMI F47 + GL marine vs UL508 only, (4) -30C minimum vs -20C, (5) 3KVac I/P-O/P vs 3KVac (same), (6) time-adaptive overload vs fixed CC, (7) no DC OK LED/relay. The SDR-75 is the more rugged, peak-power-capable choice for demanding industrial and marine applications.

What does SEMI F47 certification mean?

SEMI F47 is the semiconductor industry standard for voltage sag immunity. Certified power supplies must continue operating through specified voltage dips without interruption — critical for semiconductor manufacturing where a momentary power glitch can ruin an entire wafer batch worth millions. The SDR-75's 80ms hold-up at 230V directly supports this requirement.

Does the SDR-75 have DC OK monitoring?

No. The SDR-75 does not include a DC OK relay or LED indicator. For remote status monitoring, consider the NDR-75 (LED on 48V) or XDR-75E (relay on all models).

Is the hold-up time really 80ms?

Yes, at 230Vac input and full load. At 115Vac, hold-up is 20ms — still competitive for the class. The 80ms at 230V is exceptional and directly supports SEMI F47 compliance for voltage sag ride-through.

Related Products

All three models feature 150% peak power, 80ms hold-up, UL508, SEMI F47, GL marine reference, and Class B heavy industrial EMC.

Available Models

  • SDR-75-12 - 12V / 6.3A / 75.6W / Peak 9.375A / 88.5% efficiency
  • SDR-75-24 - 24V / 3.2A / 76.8W / Peak 4.69A / 89% efficiency
  • SDR-75-48 - 48V / 1.6A / 76.8W / Peak 2.34A / 90% efficiency

INQUIRY US

whatsapp

Email

Phone