107.5 x 67 x 36mm | 90~264VAC / 135~370VDC Input | 4 Triple-Output Models (+5V/+12V/-5V, +5V/+12V/-12V, +5V/+15V/-15V, +16V/+48V/-16V) | 28.5W~37.77W Total | 2-Pole IEC320-C8 AC Inlet | Class II Double Insulation | Efficiency 80%~85% Level VI | No-Load <0.3W | Leakage 0.75mA Max | -20~+70C | 3-Year Warranty
The MEAN WELL GP25B series is a 25W-class AC-DC triple output industrial desktop adapter. Each model provides three independent rails - a fixed +5V logic rail plus a positive/negative pair - so one adapter can power the digital, analogue and bias sections of the same device without stacking three single-output supplies. Mains connection is a 2-pole IEC320-C8 inlet on a Class II double-insulated construction with no earth pin, so a two-core mains cord is sufficient, and the input covers 90~264VAC (or 135~370VDC) at 47~63Hz.
Four models cover the common rail combinations: +5V/+12V/-5V (GP25B13A-R1B), +5V/+12V/-12V (GP25B13D-R1B), +5V/+15V/-15V (GP25B14E-R1B) and the optional +16V/+48V/-16V (GP25B58F-R1B), which MEAN WELL lists for video-system use. Total rated power is the sum of the three rails and is therefore higher than the 25W in the series name: 28.5W / 28W / 29W, and 37.77W on the optional 58F.
Efficiency is 80% to 85% depending on model with no-load consumption below 0.3W, meeting Efficiency Level VI and the mandatory USA EISA 2007/DoE requirement. The multi-output Level VI limit for this power class is looser than the single-output curve, which is why the efficiency figures sit below those of a single-output adapter of the same wattage. Safety approvals cover IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004, with BS EN/EN62368-1 covering the three standard models but expressly excluding the optional GP25B58F-R1B.
Protections are short circuit, overload at 110%~160% of rated power in hiccup mode with automatic recovery, and over-voltage by diode clamp - specified on the 5V rail only. Because the rails interact, the datasheet also publishes a ±15% cross regulation figure measured between 20% and full load. The output cable is UL2464 18AWG*3C plus 20AWG*2C at 1530mm, the standard plug is the R1B DIN 5-pin male, and the unit operates from -20C to +70C in a 107.5 x 67 x 36mm 94V-0 housing backed by a 3-year warranty.
Each GP25B model carries three outputs. Total rated power is the sum of the three rails, which is why it exceeds the 25W in the series name. All values measured at 230VAC input, rated load, 25C / 70%RH unless otherwise noted; DC voltage is measured at the connector terminals at 50% load.
| Model | Output 1 | Output 2 | Output 3 | Total Rated Power (Max) | Efficiency (Typ.) |
|---|---|---|---|---|---|
| GP25B13A-R1B | 5V / 2.5A | 12V / 1.2A | -5V / 0.3A | 28.5W | 80% |
| GP25B13D-R1B | 5V / 2.5A | 12V / 1A | -12V / 0.3A | 28W | 80% |
| GP25B14E-R1B | 5V / 2.5A | 15V / 0.8A | -15V / 0.3A | 29W | 80.5% |
| GP25B58F-R1B (optional) | 16V / 1.05A | 48V / 0.087A | -16V / 1.05A | 37.77W | 85% |
| Model | Output 1 Range | Output 2 Range | Output 3 Range |
|---|---|---|---|
| GP25B13A-R1B | 0.5 ~ 2.5A | 0.2 ~ 1.2A | 0.1 ~ 0.3A |
| GP25B13D-R1B | 0.5 ~ 2.5A | 0.2 ~ 1A | 0.1 ~ 0.3A |
| GP25B14E-R1B | 0.5 ~ 2.5A | 0.1 ~ 0.8A | 0.1 ~ 0.3A |
| GP25B58F-R1B | 0.2 ~ 1.05A | 17mA ~ 87mA | 0.2 ~ 1.05A |
| Model | Output | Ripple & Noise (Max) | Voltage Tolerance | Line Regulation | Load Regulation |
|---|---|---|---|---|---|
| GP25B13A-R1B | Output 1 (5V) | 50mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP25B13A-R1B | Output 2 (12V) | 100mVp-p | -5.0 ~ +10% | ±1.0% | ±5.0% |
| GP25B13A-R1B | Output 3 (-5V) | 50mVp-p | ±3.0% | ±1.0% | ±3.0% |
| GP25B13D-R1B | Output 1 (5V) | 60mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP25B13D-R1B | Output 2 (12V) | 120mVp-p | -5.0 ~ +5.0% | ±1.0% | ±5.0% |
| GP25B13D-R1B | Output 3 (-12V) | 50mVp-p | ±3.0% | ±1.0% | ±3.0% |
| GP25B14E-R1B | Output 1 (5V) | 100mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP25B14E-R1B | Output 2 (15V) | 150mVp-p | -5.0 ~ +15% | ±1.0% | ±5.0% |
| GP25B14E-R1B | Output 3 (-15V) | 50mVp-p | ±3.0% | ±1.0% | ±3.0% |
| GP25B58F-R1B | Output 1 (16V) | 200mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP25B58F-R1B | Output 2 (48V) | 200mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP25B58F-R1B | Output 3 (-16V) | 200mVp-p | -5.0 ~ +10% | ±1.0% | ±5.0% |
Voltage tolerance includes set-point error plus line and load regulation. Ripple and noise are measured with a 12 inch twisted pair terminated by 0.1uF and 47uF capacitors in parallel over a 20MHz bandwidth. Cross regulation between outputs is ±15%, specified with the load swept between 20% and 100% of rated load.
| DIN 5-Pin Male Pin | Output | Tinned Lead (Optional) | Output |
|---|---|---|---|
| 1 | COM | 1 (black) | COM |
| 2 | COM | 2 (blue) | COM |
| 3 | +5VDC | 3 (red) | +5VDC |
| 4 | -Vout | 4 (white) | -Vout |
| 5 | +Vout | 5 (yellow) | +Vout |
The standard DC plug is R1B, a DIN 5-pin male connector. The only alternative published in the datasheet is a stripped and tinned lead set, which is a custom item: standard length L 70mm and L1 10mm, both adjustable to customer requirement, supplied with heat-shrink sleeving and no earth lead - the C8 inlet has no earth pin. On GP25B58F-R1B the first rail is 16V rather than 5V while the datasheet pin table still prints +5VDC on pin 3 - confirm the pin allocation with MEAN WELL before wiring that model.
| AC Input Range | 90~264VAC | 135~370VDC | 47~63Hz |
| AC Inlet | 2-pole IEC320-C8 inlet | Class II double insulation, no earth pin |
| AC Current (Typ.) | 0.8A / 100VAC | 0.4A / 230VAC |
| Inrush Current (Max.) | Cold start 30A / 115VAC | 60A / 230VAC |
| Leakage Current (Max.) | 0.75mA / 240VAC |
| Efficiency | 80% (13A) / 80% (13D) / 80.5% (14E) / 85% (58F) | Efficiency Level VI for the whole series | Complies with USA EISA 2007/DoE |
| No-Load Power Consumption | <0.3W |
| Set Up / Rise / Hold-Up Time | 800ms, 50ms, 20ms / 230VAC | 1200ms, 50ms, 16ms / 115VAC at full load |
| Overload Protection | 110%~160% of rated output power | Hiccup mode, auto-recovery after the fault condition is removed |
| Over-Voltage Protection | 110%~160% of rated output voltage on the 5V output only | Diode clamp, output short-circuit protection |
| Cross Regulation | ±15% cross regulation (measured between 20% and full rated load; load regulation ±5.0% over the same range) |
| Operating Temp / Humidity | -20~+70C (refer to derating curve) | 20~90% RH non-condensing |
| Storage Temp / Humidity | -20~+85C | 10~95% RH non-condensing |
| Temp Coefficient | ±0.03%/C (-20~40C) |
| Vibration | 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis |
| DC Output Cable | UL2464 18AWG*3C & 20AWG*2C 1530+150/-0mm |
| MTBF | ≥620K hrs min. MIL-HDBK-217F (25C) |
| Dimensions / Packing | 107.5 x 67 x 36mm (L*W*H) | 0.3kg; 54pcs / 20kg / carton |
| Life | 3 years at 100% load, 40C, 8 hours per day |
| Safety Standards | IEC62368-1; UL62368-1; CSA22.2; BS EN/EN62368-1 (except GP25B58F-R1B); EAC TP TC 004 |
| Protection Class | Class II (2-pole IEC320-C8 inlet, double insulation, no earth pin) |
| Withstand Voltage | I/P-O/P: 4242VDC | the datasheet also prints I/P-FG: 2121VDC, although the 2-pole C8 inlet has no earth pin |
| Insulation Resistance | I/P-O/P: 100M Ohms / 500VDC / 25C / 70% RH (datasheet also lists I/P-FG) |
| EMC Emission | Conducted emission: BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) - Class B | Radiated emission: same standards, Class B | Harmonic current: BS EN/EN61000-3-2 Class A | Voltage flicker: BS EN/EN61000-3-3 |
| EMC Immunity | ESD BS EN/EN61000-4-2 Level 3 (8KV air) / Level 2 (4KV contact) | RF field BS EN/EN61000-4-3 Level 2, 3V/m | EFT bursts BS EN/EN61000-4-4 Level 2, 1KV | Surge BS EN/EN61000-4-5 Level 3, 1KV line-line | Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V | Voltage dips and interruption BS EN/EN61000-4-11 (>95% dip 0.5 period, 30% dip 25 periods, >95% interruption 250 periods) |
| Housing / Protections | 94V-0 flame-retardant fully enclosed plastic housing | Protections: short circuit / overload / over voltage | Power-on LED indicator |
| Warranty | 3 years |
The series name says 25W, but actual rated power is the sum of the three outputs and is therefore higher: 28.5W on GP25B13A-R1B (+5V 2.5A, +12V 1.2A, -5V 0.3A), 28W on GP25B13D-R1B (+5V 2.5A, +12V 1A, -12V 0.3A), 29W on GP25B14E-R1B (+5V 2.5A, +15V 0.8A, -15V 0.3A), and 37.77W on the optional GP25B58F-R1B (+16V 1.05A, +48V 0.087A, -16V 1.05A). Treat 25W as the platform class, not the output limit.
13A gives +5V/+12V/-5V, 13D gives +5V/+12V/-12V, and 14E gives +5V/+15V/-15V. Choose 13D when you need a symmetrical ±12V analogue supply, and 14E when you need ±15V for op-amp or audio stages. 58F is different: it provides +16V/+48V/-16V with no 5V rail, is listed by MEAN WELL for video-system use, and is an optional model.
IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004, with BS EN/EN62368-1 also covering GP25B13A-R1B, GP25B13D-R1B and GP25B14E-R1B. BS EN/EN62368-1 expressly excludes the optional GP25B58F-R1B in the datasheet, so do not assume the European approval for that model without confirming the certificate with MEAN WELL. Emissions meet Class B limits to BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B)/NMB-3(B).
No. Over-voltage protection is a diode clamp specified on the 5V output only, combined with output short-circuit protection. Overload protection is common to the adapter and trips at 110%~160% of rated output power in hiccup mode, recovering automatically once the fault is removed. GP25B58F-R1B has no 5V rail at all, so the 5V clamp clause does not describe that model.
When you load one rail heavily the other rails can drift slightly. MEAN WELL publishes a ±15% cross regulation figure for the GP25B series, measured with the load swept between 20% and full rated load, while load regulation on a single rail is ±5.0%. If your circuit is sensitive to rail interaction, verify the actual deviation under your own load profile rather than assuming each rail is independent.
The standard plug is R1B, a DIN 5-pin male connector, with pin 1 and 2 as COM, pin 3 as +5VDC, pin 4 as -Vout and pin 5 as +Vout. The output cable is UL2464 18AWG*3C plus 20AWG*2C, 1530+150/-0mm. The only alternative in the datasheet is a stripped and tinned lead set, which is a custom item with L 70mm and L1 10mm as standard; GP25B has no earth lead.
No. GP25B is an industrial ITE adapter certified to the 62368-1 family with no patient-protection rating. For equipment with patient contact use a 60601-1 certified adapter with 2xMOPP isolation from the MEAN WELL GSM medical series. As with any component supply, EMC and safety of the complete system must be confirmed in the end device.
Every triple-output combination in the GP25B family.
Mobile:+8615397378162
Tel:+86-577-89887719
Whatsapp:+8615397378162
Email:info@ledluxhub.com
Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA