GST360B Series - 360W Fanless Desktop Adapter with 450W Peak Power, Class II, 2-Pole IEC320-C18 Inlet, 6 Output Models 12V ~ 55VDC, Level VI

220 x 95 x 46mm | 85~264VAC / 120~370VDC Input | 6 Output Models 12V ~ 55VDC | 330W ~ 360W Rated, up to 450W Peak for 3s | 2-Pole IEC320-C18 AC Inlet | Class II Double Insulated, No Earth Required | Active PFC, PF>0.95 | Fanless Design | No-Load <0.5W | Efficiency Level VI, up to 95% | Contact Current <0.5mA | C8P 8-Pin (12~15V) and C6P 6-Pin (24~55V) Standard Plugs | -30~+70C | 3-Year Warranty

In Stock 3-Year Warranty Efficiency Level VI Class II IEC320-C18 Inlet Active PFC Fanless 450W Peak (3s)

Key Performance at a Glance

360W
Rated Power (24~55V)
450W
Peak Power for 3s
95%
Peak Efficiency
6
Output Voltages
Class II
Protection Class
Fanless
Cooling

Product Overview

The MEAN WELL GST360B series is a high-reliability 360W-class AC-DC desktop single-output green adapter built into a fully enclosed, fanless plastic housing. It connects to mains through a 2-pole IEC320-C18 inlet and is a Class II power supply with double insulation, so no protective earth is required and the adapter can be run from a two-wire mains supply. Input range is 85~264VAC or 120~370VDC, and the series covers six output voltages from 12V to 55VDC - 12V, 15V, 24V, 36V, 48V and 55V, with no 20V model - serving consumer electronic devices, telecom equipment, office equipment and industrial equipment.

What separates the GST360B from the smaller GST platforms is peak power: every model delivers roughly 1.25 times its rated power for 3 seconds - 415W on the 12V model, 425W on 15V and 450W on 24V through 55V. That headroom absorbs motor inrush and capacitive start-up loads that would otherwise force a larger, more expensive adapter. Rated power itself is not a flat 360W: 12V is 330W, 15V is 340.5W, and only the 24V, 36V, 48V and 55V models reach the full 360W.

The input stage uses active power factor correction, with power factor above 0.95 at 230VAC and above 0.98 at 115VAC at full load, drawing 3.8A at 115VAC and 2A at 230VAC. Double insulation holds the touch current below 0.5mA at 260VAC, and the 94V-0 flame-retardant fully sealed housing leaves no live part exposed in normal operation. Withstand voltage is 3KVAC input-to-output with insulation resistance of 100M Ohms minimum at 500VDC; there is no input-to-earth rating because the product has no earth terminal. Typical efficiency runs from 91% on 12V to 95% on the 48V and 55V models, meeting Efficiency Level VI with no-load consumption published as below 0.5W - the Level VI ceiling for the above-250W band, so it is compliant rather than a regression. This is an ITE product certified to the 62368-1 and 61558 families: for patient-contact medical equipment choose a 60601-1 certified adapter from the GSM series instead.

The standard output connector is voltage-dependent on this series: 12V and 15V ship with the C8P, an 8-pin MOLEX 39-01-2080 equivalent carrying four +Vo and four -Vo pins on a 27.5A / 22.7A output; 24V through 55V ship with the C6P, a 6-pin MOLEX 39-01-2060 equivalent with three +Vo and three -Vo pins. Note that C8P and C6P are the DC output connectors - the AC inlet on this series is the C18, not the C8. Protections cover short circuit, overload (135%~155% of rated power - hiccup and auto-recovery on 12~36V, shutdown and restart on 48V and 55V), over voltage (105%~135% of rated output voltage, shutdown with restart) and over temperature (shutdown with restart). The 220 x 95 x 46mm adapter weighs 1.4Kg, operates from -30C to +70C and is backed by a 3-year warranty.

Product Images

GST360B series 360W fanless desktop adapter with 450W peak power and IEC320-C18 inlet product image
GST360B series C8P 8-pin and C6P 6-pin standard DC output connector pin definition
GST360B series desktop adapter 220 x 95 x 46mm dimension drawing

Technical Specifications

Output ratings for all six GST360B models. All values measured at 230VAC input, rated load, 25C / 70%RH unless otherwise noted.

Model Output Voltage Rated Current Current Range Rated Power (Max) Peak Power (3s) Efficiency (Typ.)
GST360B12-C8P 12V 27.5A 0 ~ 27.5A 330W 415W 91%
GST360B15-C8P 15V 22.7A 0 ~ 22.7A 340.5W 425W 92%
GST360B24-C6P 24V 15A 0 ~ 15A 360W 450W 93%
GST360B36-C6P 36V 10A 0 ~ 10A 360W 450W 94%
GST360B48-C6P 48V 7.5A 0 ~ 7.5A 360W 450W 95%
GST360B55-C6P 55V 6.55A 0 ~ 6.55A 360W 450W 95%

Rated power is 330W on 12V, 340.5W on 15V, and 360W on 24V / 36V / 48V / 55V - only four of the six models reach the 360W nominal. Peak power for 3 seconds is published separately (415W / 425W / 450W) and is a transient rating, not a continuous one. The series covers six voltages and there is no 20V model; 55V is the highest output offered in a GST desktop adapter.

Model Ripple & Noise (Max) Voltage Tolerance Line Regulation Load Regulation
GST360B12-C8P 120mVp-p ±5.0% ±1.0% ±5.0%
GST360B15-C8P 120mVp-p ±5.0% ±1.0% ±5.0%
GST360B24-C6P 200mVp-p ±3.0% ±1.0% ±3.0%
GST360B36-C6P 200mVp-p ±2.0% ±1.0% ±2.0%
GST360B48-C6P 200mVp-p ±2.0% ±1.0% ±2.0%
GST360B55-C6P 200mVp-p ±2.0% ±1.0% ±2.0%

Overload protection is rated 135%~155% of rated output power across the series, but the response changes at 48V: the 12V, 15V, 24V and 36V models enter hiccup mode and recover automatically once the fault is removed, while the 48V and 55V models shut the output down and require a restart. Over-voltage protection trips at 105%~135% of rated output voltage with output shutdown and restart on every model, and over-temperature protection behaves the same way. All three are listed in the Input & Protection table below.

DC Plug & Connector Options

Style Type Model Pin Definition
Standard on 12V / 15V 8-pin, MOLEX 39-01-2080 or equivalent C8P Pins 1, 2, 3, 4 +Vo | Pins 5, 6, 7, 8 -Vo
Standard on 24V ~ 55V 6-pin, MOLEX 39-01-2060 or equivalent C6P Pins 1, 2, 3 +Vo | Pins 4, 5, 6 -Vo
XLR 4 Pin (optional) NEUTRIK NC4FX equivalent, 36~55V only MIC4 Pin 1 +Vo | Pin 2 +Vo | Pin 3 -Vo | Pin 4 -Vo
4 Pin (optional) AMP 1-480702-0 (6.35mm) equivalent, 36~55V only C4P Pin 1 +Vo | Pin 2 +Vo | Pin 3 -Vo | Pin 4 -Vo

Note: the GST360B publishes two standard plugs split by voltage - C8P on 12V and 15V, C6P on 24V to 55V - and only two optional plugs, MIC4 and C4P, both restricted to 36~55V. There is no R7BF on this series, no tuning-fork 5.5mm plug and no quick-change adapter. For the 12V, 15V and 24V models no optional plug is published at all, so those voltages ship with their standard connector. C8P and C6P are output connectors; the AC inlet is a 2-pole IEC320-C18.

Input & Protection (All Models)

AC Input Range 85~264VAC | 47~63Hz
DC Input Range 120~370VDC
AC Inlet 2-pole IEC320-C18 inlet | Class II construction, double insulated, no protective earth
Power Factor (Typ.) PF>0.95 / 230VAC | PF>0.98 / 115VAC at full load | Active PFC
AC Current (Typ.) 3.8A / 115VAC | 2A / 230VAC
Inrush Current (Max.) Cold start 95A / 115VAC | 120A / 230VAC
Leakage Current (Max.) Contact current <0.5mA / 260VAC
Efficiency (Typ.) 91% / 92% / 93% / 94% / 95% / 95% on 12V / 15V / 24V / 36V / 48V / 55V | Efficiency Level VI for the whole series | Complies with USA EISA 2007/DoE and Canada NRCan
No-Load Power Consumption <0.5W
Peak Power Output 3-second peak on every model: 415W (12V) / 425W (15V) / 450W (24V, 36V, 48V, 55V)
Set Up / Rise Time 2000ms, 50ms / 230VAC | 2000ms, 50ms / 115VAC at full load
Hold Up Time (Typ.) 8ms / 230VAC | 8ms / 115VAC at full load
Overload Protection 135%~155% of rated output power | 12V, 15V, 24V, 36V: hiccup mode, auto-recovery once the fault condition is removed | 48V, 55V: output shutdown, restart to recover
Over-Voltage Protection 105%~135% of rated output voltage | Output shutdown, restart to recover
Over-Temperature Protection Output shutdown, restart to recover
Operating Temp / Humidity -30~+70C, fanless design (refer to derating curve) | 20~90% RH non-condensing
Storage Temp / Humidity -40~+85C | 10~95% RH non-condensing
Temp Coefficient ±0.03%/C (0~35C)
Vibration 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis
Operating Altitude 5000m (overvoltage category II, per UL62368-1 / BS EN/EN62368-1) | Above 2000m derate ambient by 3.5C per 1000m on fanless models
DC Output Cable 12V / 15V: UL2464 16AWG x 6C 1000±50mm | 24V / 36V / 48V / 55V: UL2464 16AWG x 4C 1000±50mm
MTBF 2057.2K hrs min. Telcordia SR-332 (Bellcore) | 265.9K hrs min. MIL-HDBK-217F (25C)
Dimensions / Packing 220 x 95 x 46mm (L*W*H) | 1.4Kg; 8pcs / 12Kg / 0.82CUFT per carton
Enclosure Model / Indicator Enclosure model GS280A | Power-on LED indicator on the housing

Safety Standards & Certifications

ITE Safety Standards UL62368-1; CSA C22.2 No.62368-1; Dekra BS EN/EN62368-1; IEC 61558-1; IEC 61558-2-16; CCC GB4943.1; AS/NZS 61558-1/-2-16; EAC TP TC 004
Protection Class Class II (double insulated, no protective earth; 2-pole IEC320-C18 inlet)
Withstand Voltage I/P-O/P: 3KVAC
Insulation Resistance I/P-O/P: 100M Ohms / 500VDC / 25C / 70% RH
EMC Emission Conducted emission: BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B), EAC TP TC 020 - Class B | Radiated emission: same standards, Class B | Harmonic current: BS EN/EN61000-3-2 Class A | Voltage flicker: BS EN/EN61000-3-3
EMC Immunity ESD BS EN/EN61000-4-2 Level 4 (15KV air) / Level 4 (8KV contact) | RF field BS EN/EN61000-4-3 Level 2, 3V/m | EFT bursts BS EN/EN61000-4-4 Level 2, 1KV | Surge BS EN/EN61000-4-5 Level 3, 1KV line-line | Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V | Magnetic field BS EN/EN61000-4-8 Level 2, 3A/m | Voltage dips and interruption BS EN/EN61000-4-11
Housing / Protections 94V-0 flame-retardant fully enclosed plastic housing, fanless | Protections: short circuit / overload / over voltage / over temperature
Warranty 3 years

All six models carry the same eight-standard approval list - there is no per-model exception on this datasheet. Read it carefully if you are substituting this series for another GST desktop part: the GST360B list combines the 62368-1 family (UL, CSA, Dekra BS EN/EN, CCC GB4943.1) with the 61558 transformer standards (IEC 61558-1, IEC 61558-2-16, AS/NZS 61558-1/-2-16), and it does not include PSE J62368-1, BIS IS13252, KC 62368-1 or BSMI CNS15598-1 - those appear on the Class I GST360A, not here. The certification logo block on page 1 lists the same scope. If your tender needs the exact certificate copy for a specific model, ask us and we will send it.

Key Features

450W Peak for 3 Seconds
Every model carries a 3-second peak rating about 1.25x its continuous output: 415W on 12V, 425W on 15V and 450W on 24V to 55V. That covers motor inrush, capacitive start-up and short duty-cycle bursts without oversizing the adapter for the steady-state load.
Six Voltages, No 20V
12V / 15V / 24V / 36V / 48V / 55VDC at 330W / 340.5W / 360W x 4. The 55V model is the top of the GST desktop family, and there is no 20V version - check the voltage list before substituting a GST280A or GST220A part number.
Class II, Two-Wire Mains
Double insulation and a 2-pole IEC320-C18 inlet mean no protective earth conductor is needed. Touch current stays below 0.5mA at 260VAC, and the DC output carries no earth reference from the adapter side, which suits Class II end products and double-insulated appliances.
Fanless, Fully Sealed Housing
No fan means no inlet filter to clog, no bearing to fail and no dust path into the electronics, which suits dusty workshops and cabinets where forced-air units need scheduled maintenance. Fully enclosed 94V-0 flame-retardant plastic, rated -30C to +70C.
Active PFC, PF Above 0.95
Power factor is above 0.95 at 230VAC and above 0.98 at 115VAC at full load, with input current of 3.8A at 115VAC and 2A at 230VAC. Inrush current is limited to 95A at 115VAC and 120A at 230VAC cold start.
Two Standard Plugs by Voltage
12V and 15V use the C8P 8-pin plug, splitting 27.5A and 22.7A across four +Vo and four -Vo pins; 24V to 55V use the C6P 6-pin plug. The model suffix always matches the fitted connector - C8P for 12~15V, C6P for 24~55V.
Level VI Efficiency, 91% to 95%
Typical efficiency from 91% on 12V to 95% on 48V and 55V, with no-load consumption below 0.5W. The whole series meets Efficiency Level VI and complies with USA EISA 2007/DoE and Canada NRCan.

Frequently Asked Questions

Which safety standards and certifications does the GST360B series carry?

All six models are certified to UL62368-1, CSA C22.2 No.62368-1, Dekra BS EN/EN62368-1, IEC 61558-1, IEC 61558-2-16, CCC GB4943.1, AS/NZS 61558-1/-2-16 and EAC TP TC 004. There is no per-model exception. Note that this is a shorter list than the Class I GST360A: the GST360B does not carry PSE J62368-1, BIS IS13252, KC 62368-1 or BSMI CNS15598-1. Conducted and radiated emissions meet Class B limits to BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) and EAC TP TC 020.

What is the difference between GST360B and GST360A?

They share the same 360W platform, the same six output voltages (12/15/24/36/48/55V), the same three-second peak ratings and the same C8P / C6P output connectors, but the mains interface and the safety layer are different. GST360B is Class II: double insulated, 2-pole IEC320-C18 inlet, no protective earth, touch current below 0.5mA. GST360A is Class I: 3-pole IEC320-C14 inlet with protective earth, 1.5mA leakage, and additional input-to-earth withstand (2KVAC) and surge (2KV line-FG) ratings. The A series also carries a longer approval list. If your end product must be double-insulated or has no earth conductor, take the B; if it is earthed Class I equipment, take the A.

What does the 450W peak power rating actually mean?

The GST360B is rated for 3 seconds at roughly 1.25 times its continuous output - 415W on the 12V model, 425W on 15V, and 450W on the 24V, 36V, 48V and 55V models. It is a transient allowance for motor inrush, capacitive start-up and short bursts, not a continuous rating. Size your steady-state load against the rated power (330W / 340.5W / 360W), and keep the 3-second window in mind for anything that starts repeatedly.

Is the GST360B 360W on every output voltage?

No. The datasheet rates them individually: 12V is 330W (27.5A), 15V is 340.5W (22.7A), and 24V, 36V, 48V and 55V are 360W at 15A, 10A, 7.5A and 6.55A. Quoting "360W" on a 12V requirement overstates it by 30W, and on a 15V requirement by about 20W.

Is the GST360B a Class I or a Class II power supply?

GST360B is a Class II power supply. It uses double insulation and a 2-pole IEC320-C18 mains inlet, so there is no protective earth conductor and no earth connection is required at installation. Touch current is below 0.5mA at 260VAC, and withstand voltage is 3KVAC input-to-output with no input-to-earth rating - because there is no earth terminal. If your product requires a 3-pole earthed mains input, the GST360A series with a 3-pole IEC320-C14 inlet is the Class I equivalent at the same power level.

Does the C8P connector mean the adapter has an IEC320-C8 inlet?

No, and this trips people up. On the GST360B the C8P and C6P are DC output connectors - C8P is the 8-pin MOLEX 39-01-2080 equivalent on the 12V and 15V models, C6P the 6-pin MOLEX 39-01-2060 equivalent on 24V to 55V. The AC inlet is a 2-pole IEC320-C18, which is the two-pole version of the C14 family and accepts a standard C13-style cord set with the earth contact unused. Do not order a C8 (figure-8) mains cord for this adapter.

Why is the standard plug C8P on some models and C6P on others?

Because of current. The 12V model delivers 27.5A and the 15V model 22.7A, so MEAN WELL fits the 8-pin C8P which spreads the load across four +Vo and four -Vo pins. From 24V up the current falls to 15A and below, and the 6-pin C6P is used, with three +Vo and three -Vo pins. The model suffix tells you which one you are ordering: -C8P for 12V and 15V, -C6P for 24V to 55V.

Is there a 20V version of the GST360B?

No. The GST360B covers 12V, 15V, 24V, 36V, 48V and 55V only - there is no 20V model, even though the GST280A and GST220A both have one. If a 20V design is already tooled, the GST280A20-C6P (20V / 13A / 260W) is the closest desktop option at this power level, at lower rated power.

Why is no-load consumption 0.5W when smaller GST models quote 0.15W?

Because of the power band, not because of a weaker design. Efficiency Level VI sets a no-load ceiling of 0.21W for adapters between 49W and 250W output, and 0.5W above 250W - so a 360W platform is measured against the 0.5W limit. The GST360B publishes "below 0.5W" and meets Level VI. Comparing its no-load figure with a 120W adapter's 0.15W is comparing two different regulatory bands.

What happens when the GST360B goes into overload, over-voltage or over-temperature protection?

Overload trips at 135%~155% of rated output power, but the response depends on voltage: 12V, 15V, 24V and 36V enter hiccup mode and recover automatically once the fault is removed, while 48V and 55V shut the output down and need a restart. Over-voltage (105%~135% of rated output voltage) and over-temperature protection shut the output down and require a restart on every model. If your installation is unattended, plan for a remote power cycle or size the thermal design with margin so the OTP point is never reached.

Can I use the GST360B for a medical device?

No. GST360B is an ITE product certified to the 62368-1 and 61558 standards. For equipment with patient contact, use a 60601-1 certified adapter from the MEAN WELL GSM medical series instead, which provides 2xMOPP isolation. The adapter is in any case a component intended to be built into end equipment, so EMC and safety of the complete system must be confirmed with the finished device.

Related Products

Explore every output voltage in the GST360B family.

Available Models

  • GST360B12-C8P - 12VDC / 27.5A (330W rated, 415W peak 3s) / ripple <120mVp-p / ±5.0% accuracy / 91% efficiency / Level VI / C8P standard plug
  • GST360B15-C8P - 15VDC / 22.7A (340.5W rated, 425W peak 3s) / ripple <120mVp-p / ±5.0% accuracy / 92% efficiency / Level VI / C8P standard plug
  • GST360B24-C6P - 24VDC / 15A (360W rated, 450W peak 3s) / ripple <200mVp-p / ±3.0% accuracy / 93% efficiency / Level VI / C6P standard plug
  • GST360B36-C6P - 36VDC / 10A (360W rated, 450W peak 3s) / ripple <200mVp-p / ±2.0% accuracy / 94% efficiency / Level VI / C6P standard plug
  • GST360B48-C6P - 48VDC / 7.5A (360W rated, 450W peak 3s) / ripple <200mVp-p / ±2.0% accuracy / 95% efficiency / Level VI / C6P standard plug
  • GST360B55-C6P - 55VDC / 6.55A (360W rated, 450W peak 3s) / ripple <200mVp-p / ±2.0% accuracy / 95% efficiency / Level VI / C6P standard plug

INQUIRY US

CATEGORIES

CONTACT US

Mobile:+8615397378162

Tel:+86-577-89887719

Whatsapp:+8615397378162

Email:info@ledluxhub.com

Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA

OTHER LINK