info@ledluxhub.com+8615397378162
Home     Products     MEAN WELL     Medical Grade Power Supplies       MEAN WELL Power Supply GP50A Series Trip
  • MEAN WELL Power Supply GP50A Series Triple Output Industrial Adaptor - Image 1

MEAN WELL Power Supply GP50A Series Triple Output Industrial Adaptor

  • Product Item : GP50A series
  • Category:Medical Grade Power Supplies
  • Wattage: 50W
  • Input Voltage: 90 ~ 264VAC or 135 ~ 370VDC
  • Current Range: 0.015 ~ 4A
  • DC Voltage: -15 ~ 48V
  • Product description:GP50A is a 50W triple-output desktop type green adaptor series, complying with the mandatory energysaving standard USA EISA 2007/DoE (Level V).
  • INQUIRY   EMAIL

GP50A Series - 50W Triple Output Desktop Adapter, Class I, 3-Pole IEC320-C14 Inlet, 4 Models from +5V/+12V/-5V to +16V/+48V/-16V, Level VI

146 x 75.5 x 43mm | 90~264VAC / 135~370VDC Input | 4 Triple-Output Models (+5V/+12V/-5V, +5V/+12V/-12V, +5V/+15V/-15V, +16V/+48V/-16V) | 46.5W~71.2W Total | 3-Pole IEC320-C14 AC Inlet | Class I with Earth | Efficiency 83.5%~86% Level VI | No-Load <0.3W | Leakage 0.75mA Max | -20~+70C | 3-Year Warranty

In Stock 3-Year Warranty Triple Output Efficiency Level VI Class I / IEC320-C14 No-Load <0.3W EMC Class B -20~+70C

Key Performance at a Glance

3
Outputs per Model
71.2W
Max Total Power
86%
Peak Efficiency
<0.3W
No-Load Power
Class I
With Earth
C14
AC Inlet

Product Overview

The MEAN WELL GP50A series is a 50W-class AC-DC triple output industrial desktop adapter. Each model provides three independent rails - a fixed +5V logic rail plus a positive/negative pair - so one adapter can power the digital, analogue and bias sections of the same device without stacking three single-output supplies. Mains connection is a 3-pole IEC320-C14 inlet on a Class I construction with protective earth, and the input covers 90~264VAC (or 135~370VDC) at 47~63Hz.

Four models cover the common rail combinations: +5V/+12V/-5V (GP50A13A-R1B), +5V/+12V/-12V (GP50A13D-R1B), +5V/+15V/-15V (GP50A14E-R1B) and the optional +16V/+48V/-16V (GP50A58F-R1B), which MEAN WELL lists for video-system use. Total rated power is the sum of the three rails and is therefore different from the 50W in the series name: 46.5W on the 13A, 50W on the 13D and 14E, and 71.2W on the optional 58F.

Efficiency is 83.5% to 86% depending on model with no-load consumption below 0.3W, meeting Efficiency Level VI and the mandatory USA EISA 2007/DoE requirement. The multi-output Level VI limit for this power class is looser than the single-output curve, which is why the efficiency figures sit below those of a single-output adapter of the same wattage. Safety approvals cover IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004, with BS EN/EN62368-1 covering the three standard models but expressly excluding the optional GP50A58F-R1B.

Protections are short circuit, overload at 120%~200% of rated power in hiccup mode with automatic recovery, and over-voltage by diode clamp; the datasheet does not publish a trip percentage for the clamp. Because the rails interact, a ±15% cross regulation figure is also published, measured between 20% and full load. The output cable is UL2464 18AWG*5C at 1000mm, the standard plug is the R1B DIN 5-pin male, and the unit operates from -20C to +70C in a 146 x 75.5 x 43mm 94V-0 housing backed by a 3-year warranty.

Product Images

GP50A series 50W triple output desktop adapter with IEC320-C14 inlet product image
GP50A series R1B DIN 5 pin DC output plug pin definition
GP50A series desktop adapter dimension drawing 146 x 75.5 x 43mm

Technical Specifications

Each GP50A model carries three outputs. Total rated power is the sum of the three rails, so it does not match the 50W in the series name. All values measured at 230VAC input, rated load, 25C / 70%RH unless otherwise noted; DC voltage is measured at the connector terminals at 50% load.

Triple Output Configuration & Total Rated Power

Model Output 1 Output 2 Output 3 Total Rated Power (Max) Efficiency (Typ.)
GP50A13A-R1B 5V / 4A 12V / 2A -5V / 0.5A 46.5W 83.5%
GP50A13D-R1B 5V / 4A 12V / 2A -12V / 0.5A 50W 84%
GP50A14E-R1B 5V / 4A 15V / 1.5A -15V / 0.5A 50W 84.5%
GP50A58F-R1B (optional) 16V / 2A 48V / 0.15A -16V / 2A 71.2W 86%

Output Current Range

Model Output 1 Range Output 2 Range Output 3 Range
GP50A13A-R1B 0 ~ 4.0A 0.3 ~ 2.0A 0.1 ~ 0.5A
GP50A13D-R1B 0 ~ 4.0A 0.3 ~ 2.0A 0.1 ~ 0.5A
GP50A14E-R1B 0 ~ 4.0A 0.3 ~ 1.5A 0.1 ~ 0.5A
GP50A58F-R1B 0.4 ~ 2.0A 30mA ~ 150mA 0.4 ~ 2.0A

Ripple & Noise, Accuracy and Regulation (Per Output)

Model Output Ripple & Noise (Max) Voltage Tolerance Line Regulation Load Regulation
GP50A13A-R1B Output 1 (5V) 50mVp-p ±5.0% ±1.0% ±5.0%
GP50A13A-R1B Output 2 (12V) 100mVp-p ±3.0% ±1.0% ±3.0%
GP50A13A-R1B Output 3 (-5V) 100mVp-p -5.0 ~ +10% ±1.0% ±5.0%
GP50A13D-R1B Output 1 (5V) 50mVp-p ±5.0% ±1.0% ±5.0%
GP50A13D-R1B Output 2 (12V) 150mVp-p ±3.0% ±1.0% ±3.0%
GP50A13D-R1B Output 3 (-12V) 100mVp-p -5.0 ~ +8% ±1.0% ±5.0%
GP50A14E-R1B Output 1 (5V) 50mVp-p ±5.0% ±1.0% ±5.0%
GP50A14E-R1B Output 2 (15V) 150mVp-p ±3.0% ±1.0% ±3.0%
GP50A14E-R1B Output 3 (-15V) 150mVp-p -5.0 ~ +15% ±1.0% ±5.0%
GP50A58F-R1B Output 1 (16V) 180mVp-p ±5.0% ±1.0% ±5.0%
GP50A58F-R1B Output 2 (48V) 180mVp-p -5.0 ~ +10% ±1.0% ±5.0%
GP50A58F-R1B Output 3 (-16V) 180mVp-p -5.0 ~ +10% ±1.0% ±5.0%

Voltage tolerance includes set-point error plus line and load regulation. On this series the ±3.0% tolerance sits on Output 2 and the asymmetric window (-5~+10%, -5~+8%, -5~+15%) on Output 3. Ripple and noise are measured with a 12 inch twisted pair terminated by 0.1uF and 47uF capacitors in parallel over a 20MHz bandwidth. Cross regulation between outputs is ±15%, specified with the load swept between 20% and 100% of rated load.

DC Output Plug & Pin Definition (Standard R1B)

DIN 5-Pin Male Pin Output Tinned Lead (Optional) Output
1 COM 1 (black) COM
2 COM 2 (blue) COM
3 +5VDC 3 (red) +5VDC
4 -Vout 4 (white) -Vout
5 +Vout 5 (yellow) +Vout

The standard DC plug is R1B, a DIN 5-pin male connector. The only alternative published in the datasheet is a stripped and tinned lead set, which is a custom item: standard length L 70mm and L1 10mm, both adjustable to customer requirement, supplied with FG wire and heat-shrink. On GP50A58F-R1B the first rail is 16V rather than 5V while the datasheet pin table still prints +5VDC on pin 3 - confirm the pin allocation with MEAN WELL before wiring that model.

Input & Protection (All Models)

AC Input Range 90~264VAC | 135~370VDC | 47~63Hz
AC Inlet 3-pole IEC320-C14 inlet | Class I construction with protective earth (FG)
AC Current (Typ.) 1.6A / 100VAC | 0.8A / 230VAC
Inrush Current (Max.) Cold start 35A / 115VAC | 65A / 230VAC
Leakage Current (Max.) 0.75mA / 240VAC
Efficiency 83.5% (13A) / 84% (13D) / 84.5% (14E) / 86% (58F) | Efficiency Level VI for the whole series | Complies with USA EISA 2007/DoE
No-Load Power Consumption <0.3W
Set Up / Rise / Hold-Up Time 1500ms, 50ms, 20ms / 230VAC | 2500ms, 50ms, 16ms / 115VAC at full load
Overload Protection 120%~200% of rated output power | Hiccup mode, auto-recovery after the fault condition is removed
Over-Voltage Protection Diode clamp, output short-circuit protection. The datasheet does not restrict the clamp to a named rail and publishes no over-voltage trip percentage.
Cross Regulation ±15% cross regulation (measured between 20% and full rated load; load regulation ±5.0% over the same range)
Operating Temp / Humidity -20~+70C (refer to derating curve) | 20~90% RH non-condensing
Storage Temp / Humidity -20~+85C | 10~95% RH non-condensing
Temp Coefficient ±0.03%/C (0~40C)
Vibration 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis
DC Output Cable UL2464 18AWG*5C 1000+150/-0mm
MTBF ≥280K hrs min. MIL-HDBK-217F (25C)
Dimensions / Packing 146 x 75.5 x 43mm (L*W*H) | 0.55kg; 36pcs / 21kg / carton
Life 3 years at 100% load, 40C, 8 hours per day

Safety Standards & EMC

Safety Standards IEC62368-1; UL62368-1; CSA22.2; BS EN/EN62368-1 (except GP50A58F-R1B); EAC TP TC 004
Protection Class Class I (3-pole IEC320-C14 inlet with protective earth, FG)
Withstand Voltage I/P-O/P: 4242VDC | I/P-FG: 2121VDC
Insulation Resistance I/P-O/P and I/P-FG: 100M Ohms / 500VDC / 25C / 70% RH
EMC Emission Conducted emission: BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) - Class B | Radiated emission: same standards, Class B | Harmonic current: BS EN/EN61000-3-2 Class A | Voltage flicker: BS EN/EN61000-3-3
EMC Immunity ESD BS EN/EN61000-4-2 Level 3 (8KV air) / Level 2 (4KV contact) | RF field BS EN/EN61000-4-3 Level 2, 3V/m | EFT bursts BS EN/EN61000-4-4 Level 2, 1KV | Surge BS EN/EN61000-4-5 Level 3, 1KV line-line / 2KV line-to-earth | Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V | Voltage dips and interruption BS EN/EN61000-4-11 (>95% dip 0.5 period, 30% dip 25 periods, >95% interruption 250 periods)
Housing / Protections 94V-0 flame-retardant fully enclosed plastic housing | Protections: short circuit / overload / over voltage | Power-on LED indicator
Warranty 3 years

Key Features

Three Independent Outputs in One Adapter
A fixed +5V logic rail plus a positive/negative pair per model: +5V/+12V/-5V, +5V/+12V/-12V, +5V/+15V/-15V, and +16V/+48V/-16V. One mains lead powers digital, analogue and bias sections together.
Total Power Above the 50W Nameplate
Rated power is the sum of the three rails: 46.5W on 13A, 50W on 13D, 50W on 14E and 71.2W on the optional 58F. The 50W in the series name is the platform class, not the output ceiling.
Class I, 3-Pole IEC320-C14 Inlet
Protective earth is bonded through a standard C14 inlet. Leakage is 0.75mA maximum at 240VAC, with 4242VDC input-to-output and 2121VDC input-to-earth withstand, plus 100M Ohms insulation resistance on both paths.
Level VI, No-Load Below 0.3W
Efficiency 83.5%~86% by model with no-load consumption under 0.3W. The series meets Efficiency Level VI and the mandatory USA EISA 2007/DoE requirement for this adapter class.
Wide Input, Extended Temperature
90~264VAC or 135~370VDC input at 47~63Hz, operating from -20C to +70C with derating, 20~90% RH non-condensing, and a 3-year life rating at 100% load / 40C / 8 hours per day.
94V-0 Desktop Housing
146 x 75.5 x 43mm, 0.55kg, 36pcs per 21kg carton, fully enclosed flame-retardant plastic case with rubber feet, power-on LED indicator and a 1000mm UL2464 18AWG*5C output cable.

Frequently Asked Questions

Is the GP50A a 50W power supply?

The series name says 50W, but actual rated power is the sum of the three outputs and differs by model: 46.5W on GP50A13A-R1B (+5V 4A, +12V 2A, -5V 0.5A), 50W on GP50A13D-R1B (+5V 4A, +12V 2A, -12V 0.5A), 50W on GP50A14E-R1B (+5V 4A, +15V 1.5A, -15V 0.5A), and 71.2W on the optional GP50A58F-R1B (+16V 2A, +48V 0.15A, -16V 2A). Treat 50W as the platform class, not the output limit.

Which model do I need: 13A, 13D, 14E or 58F?

13A gives +5V/+12V/-5V, 13D gives +5V/+12V/-12V, and 14E gives +5V/+15V/-15V. Choose 13D when you need a symmetrical ±12V analogue supply, and 14E when you need ±15V for op-amp or audio stages. 58F is different: it provides +16V/+48V/-16V with no 5V rail, is listed by MEAN WELL for video-system use, and is an optional model.

Which safety standards does the GP50A series hold?

IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004, with BS EN/EN62368-1 also covering GP50A13A-R1B, GP50A13D-R1B and GP50A14E-R1B. BS EN/EN62368-1 expressly excludes the optional GP50A58F-R1B in the datasheet, so do not assume the European approval for that model without confirming the certificate with MEAN WELL. Emissions meet Class B limits to BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B)/NMB-3(B).

Which outputs have over-voltage protection?

The datasheet specifies over-voltage protection as a diode clamp combined with output short-circuit protection, and it does not restrict the clamp to a named rail or publish a trip percentage - so check the behaviour on your specific load with MEAN WELL rather than assuming a figure. Overload protection is common to the adapter and trips at 120%~200% of rated output power in hiccup mode, recovering automatically once the fault is removed.

What is cross regulation and why does it matter on a triple-output adapter?

When you load one rail heavily the other rails can drift slightly. MEAN WELL publishes a ±15% cross regulation figure for the GP50A series, measured with the load swept between 20% and full rated load, while load regulation on a single rail is ±5.0%. If your circuit is sensitive to rail interaction, verify the actual deviation under your own load profile rather than assuming each rail is independent.

What DC connector and cable does the GP50A use?

The standard plug is R1B, a DIN 5-pin male connector, with pin 1 and 2 as COM, pin 3 as +5VDC, pin 4 as -Vout and pin 5 as +Vout. The output cable is UL2464 18AWG*5C, 1000+150/-0mm. The only alternative in the datasheet is a stripped and tinned lead set, which is a custom item with L 70mm and L1 10mm as standard, supplied with an FG wire.

Is the GP50A suitable for medical equipment?

No. GP50A is an industrial ITE adapter certified to the 62368-1 family with no patient-protection rating. For equipment with patient contact use a 60601-1 certified adapter with 2xMOPP isolation from the MEAN WELL GSM medical series. As with any component supply, EMC and safety of the complete system must be confirmed in the end device.

Related Products

Every triple-output combination in the GP50A family.

Available Models

  • GP50A13A-R1B - 5V / 12V / -5VDC at 4A / 2A / 0.5A (46.5W total rated power) / 83.5% efficiency / Level VI / R1B DIN 5-pin standard plug
  • GP50A13D-R1B - 5V / 12V / -12VDC at 4A / 2A / 0.5A (50W total rated power) / 84% efficiency / Level VI / R1B DIN 5-pin standard plug
  • GP50A14E-R1B - 5V / 15V / -15VDC at 4A / 1.5A / 0.5A (50W total rated power) / 84.5% efficiency / Level VI / R1B DIN 5-pin standard plug
  • GP50A58F-R1B - 16V / 48V / -16VDC at 2A / 0.15A / 2A (71.2W total rated power) / 86% efficiency / Level VI / R1B DIN 5-pin standard plug / optional model

INQUIRY US

CATEGORIES

CONTACT US

Mobile:+8615397378162

Tel:+86-577-89887719

Whatsapp:+8615397378162

Email:info@ledluxhub.com

Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA