146 x 75.5 x 43mm | 90~264VAC / 135~370VDC Input | 4 Triple-Output Models (+5V/+12V/-5V, +5V/+12V/-12V, +5V/+15V/-15V, +16V/+48V/-16V) | 46.5W~71.2W Total | 3-Pole IEC320-C14 AC Inlet | Class I with Earth | Efficiency 83.5%~86% Level VI | No-Load <0.3W | Leakage 0.75mA Max | -20~+70C | 3-Year Warranty
The MEAN WELL GP50A series is a 50W-class AC-DC triple output industrial desktop adapter. Each model provides three independent rails - a fixed +5V logic rail plus a positive/negative pair - so one adapter can power the digital, analogue and bias sections of the same device without stacking three single-output supplies. Mains connection is a 3-pole IEC320-C14 inlet on a Class I construction with protective earth, and the input covers 90~264VAC (or 135~370VDC) at 47~63Hz.
Four models cover the common rail combinations: +5V/+12V/-5V (GP50A13A-R1B), +5V/+12V/-12V (GP50A13D-R1B), +5V/+15V/-15V (GP50A14E-R1B) and the optional +16V/+48V/-16V (GP50A58F-R1B), which MEAN WELL lists for video-system use. Total rated power is the sum of the three rails and is therefore different from the 50W in the series name: 46.5W on the 13A, 50W on the 13D and 14E, and 71.2W on the optional 58F.
Efficiency is 83.5% to 86% depending on model with no-load consumption below 0.3W, meeting Efficiency Level VI and the mandatory USA EISA 2007/DoE requirement. The multi-output Level VI limit for this power class is looser than the single-output curve, which is why the efficiency figures sit below those of a single-output adapter of the same wattage. Safety approvals cover IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004, with BS EN/EN62368-1 covering the three standard models but expressly excluding the optional GP50A58F-R1B.
Protections are short circuit, overload at 120%~200% of rated power in hiccup mode with automatic recovery, and over-voltage by diode clamp; the datasheet does not publish a trip percentage for the clamp. Because the rails interact, a ±15% cross regulation figure is also published, measured between 20% and full load. The output cable is UL2464 18AWG*5C at 1000mm, the standard plug is the R1B DIN 5-pin male, and the unit operates from -20C to +70C in a 146 x 75.5 x 43mm 94V-0 housing backed by a 3-year warranty.
Each GP50A model carries three outputs. Total rated power is the sum of the three rails, so it does not match the 50W in the series name. All values measured at 230VAC input, rated load, 25C / 70%RH unless otherwise noted; DC voltage is measured at the connector terminals at 50% load.
| Model | Output 1 | Output 2 | Output 3 | Total Rated Power (Max) | Efficiency (Typ.) |
|---|---|---|---|---|---|
| GP50A13A-R1B | 5V / 4A | 12V / 2A | -5V / 0.5A | 46.5W | 83.5% |
| GP50A13D-R1B | 5V / 4A | 12V / 2A | -12V / 0.5A | 50W | 84% |
| GP50A14E-R1B | 5V / 4A | 15V / 1.5A | -15V / 0.5A | 50W | 84.5% |
| GP50A58F-R1B (optional) | 16V / 2A | 48V / 0.15A | -16V / 2A | 71.2W | 86% |
| Model | Output 1 Range | Output 2 Range | Output 3 Range |
|---|---|---|---|
| GP50A13A-R1B | 0 ~ 4.0A | 0.3 ~ 2.0A | 0.1 ~ 0.5A |
| GP50A13D-R1B | 0 ~ 4.0A | 0.3 ~ 2.0A | 0.1 ~ 0.5A |
| GP50A14E-R1B | 0 ~ 4.0A | 0.3 ~ 1.5A | 0.1 ~ 0.5A |
| GP50A58F-R1B | 0.4 ~ 2.0A | 30mA ~ 150mA | 0.4 ~ 2.0A |
| Model | Output | Ripple & Noise (Max) | Voltage Tolerance | Line Regulation | Load Regulation |
|---|---|---|---|---|---|
| GP50A13A-R1B | Output 1 (5V) | 50mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP50A13A-R1B | Output 2 (12V) | 100mVp-p | ±3.0% | ±1.0% | ±3.0% |
| GP50A13A-R1B | Output 3 (-5V) | 100mVp-p | -5.0 ~ +10% | ±1.0% | ±5.0% |
| GP50A13D-R1B | Output 1 (5V) | 50mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP50A13D-R1B | Output 2 (12V) | 150mVp-p | ±3.0% | ±1.0% | ±3.0% |
| GP50A13D-R1B | Output 3 (-12V) | 100mVp-p | -5.0 ~ +8% | ±1.0% | ±5.0% |
| GP50A14E-R1B | Output 1 (5V) | 50mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP50A14E-R1B | Output 2 (15V) | 150mVp-p | ±3.0% | ±1.0% | ±3.0% |
| GP50A14E-R1B | Output 3 (-15V) | 150mVp-p | -5.0 ~ +15% | ±1.0% | ±5.0% |
| GP50A58F-R1B | Output 1 (16V) | 180mVp-p | ±5.0% | ±1.0% | ±5.0% |
| GP50A58F-R1B | Output 2 (48V) | 180mVp-p | -5.0 ~ +10% | ±1.0% | ±5.0% |
| GP50A58F-R1B | Output 3 (-16V) | 180mVp-p | -5.0 ~ +10% | ±1.0% | ±5.0% |
Voltage tolerance includes set-point error plus line and load regulation. On this series the ±3.0% tolerance sits on Output 2 and the asymmetric window (-5~+10%, -5~+8%, -5~+15%) on Output 3. Ripple and noise are measured with a 12 inch twisted pair terminated by 0.1uF and 47uF capacitors in parallel over a 20MHz bandwidth. Cross regulation between outputs is ±15%, specified with the load swept between 20% and 100% of rated load.
| DIN 5-Pin Male Pin | Output | Tinned Lead (Optional) | Output |
|---|---|---|---|
| 1 | COM | 1 (black) | COM |
| 2 | COM | 2 (blue) | COM |
| 3 | +5VDC | 3 (red) | +5VDC |
| 4 | -Vout | 4 (white) | -Vout |
| 5 | +Vout | 5 (yellow) | +Vout |
The standard DC plug is R1B, a DIN 5-pin male connector. The only alternative published in the datasheet is a stripped and tinned lead set, which is a custom item: standard length L 70mm and L1 10mm, both adjustable to customer requirement, supplied with FG wire and heat-shrink. On GP50A58F-R1B the first rail is 16V rather than 5V while the datasheet pin table still prints +5VDC on pin 3 - confirm the pin allocation with MEAN WELL before wiring that model.
| AC Input Range | 90~264VAC | 135~370VDC | 47~63Hz |
| AC Inlet | 3-pole IEC320-C14 inlet | Class I construction with protective earth (FG) |
| AC Current (Typ.) | 1.6A / 100VAC | 0.8A / 230VAC |
| Inrush Current (Max.) | Cold start 35A / 115VAC | 65A / 230VAC |
| Leakage Current (Max.) | 0.75mA / 240VAC |
| Efficiency | 83.5% (13A) / 84% (13D) / 84.5% (14E) / 86% (58F) | Efficiency Level VI for the whole series | Complies with USA EISA 2007/DoE |
| No-Load Power Consumption | <0.3W |
| Set Up / Rise / Hold-Up Time | 1500ms, 50ms, 20ms / 230VAC | 2500ms, 50ms, 16ms / 115VAC at full load |
| Overload Protection | 120%~200% of rated output power | Hiccup mode, auto-recovery after the fault condition is removed |
| Over-Voltage Protection | Diode clamp, output short-circuit protection. The datasheet does not restrict the clamp to a named rail and publishes no over-voltage trip percentage. |
| Cross Regulation | ±15% cross regulation (measured between 20% and full rated load; load regulation ±5.0% over the same range) |
| Operating Temp / Humidity | -20~+70C (refer to derating curve) | 20~90% RH non-condensing |
| Storage Temp / Humidity | -20~+85C | 10~95% RH non-condensing |
| Temp Coefficient | ±0.03%/C (0~40C) |
| Vibration | 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis |
| DC Output Cable | UL2464 18AWG*5C 1000+150/-0mm |
| MTBF | ≥280K hrs min. MIL-HDBK-217F (25C) |
| Dimensions / Packing | 146 x 75.5 x 43mm (L*W*H) | 0.55kg; 36pcs / 21kg / carton |
| Life | 3 years at 100% load, 40C, 8 hours per day |
| Safety Standards | IEC62368-1; UL62368-1; CSA22.2; BS EN/EN62368-1 (except GP50A58F-R1B); EAC TP TC 004 |
| Protection Class | Class I (3-pole IEC320-C14 inlet with protective earth, FG) |
| Withstand Voltage | I/P-O/P: 4242VDC | I/P-FG: 2121VDC |
| Insulation Resistance | I/P-O/P and I/P-FG: 100M Ohms / 500VDC / 25C / 70% RH |
| EMC Emission | Conducted emission: BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) - Class B | Radiated emission: same standards, Class B | Harmonic current: BS EN/EN61000-3-2 Class A | Voltage flicker: BS EN/EN61000-3-3 |
| EMC Immunity | ESD BS EN/EN61000-4-2 Level 3 (8KV air) / Level 2 (4KV contact) | RF field BS EN/EN61000-4-3 Level 2, 3V/m | EFT bursts BS EN/EN61000-4-4 Level 2, 1KV | Surge BS EN/EN61000-4-5 Level 3, 1KV line-line / 2KV line-to-earth | Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V | Voltage dips and interruption BS EN/EN61000-4-11 (>95% dip 0.5 period, 30% dip 25 periods, >95% interruption 250 periods) |
| Housing / Protections | 94V-0 flame-retardant fully enclosed plastic housing | Protections: short circuit / overload / over voltage | Power-on LED indicator |
| Warranty | 3 years |
The series name says 50W, but actual rated power is the sum of the three outputs and differs by model: 46.5W on GP50A13A-R1B (+5V 4A, +12V 2A, -5V 0.5A), 50W on GP50A13D-R1B (+5V 4A, +12V 2A, -12V 0.5A), 50W on GP50A14E-R1B (+5V 4A, +15V 1.5A, -15V 0.5A), and 71.2W on the optional GP50A58F-R1B (+16V 2A, +48V 0.15A, -16V 2A). Treat 50W as the platform class, not the output limit.
13A gives +5V/+12V/-5V, 13D gives +5V/+12V/-12V, and 14E gives +5V/+15V/-15V. Choose 13D when you need a symmetrical ±12V analogue supply, and 14E when you need ±15V for op-amp or audio stages. 58F is different: it provides +16V/+48V/-16V with no 5V rail, is listed by MEAN WELL for video-system use, and is an optional model.
IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004, with BS EN/EN62368-1 also covering GP50A13A-R1B, GP50A13D-R1B and GP50A14E-R1B. BS EN/EN62368-1 expressly excludes the optional GP50A58F-R1B in the datasheet, so do not assume the European approval for that model without confirming the certificate with MEAN WELL. Emissions meet Class B limits to BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B)/NMB-3(B).
The datasheet specifies over-voltage protection as a diode clamp combined with output short-circuit protection, and it does not restrict the clamp to a named rail or publish a trip percentage - so check the behaviour on your specific load with MEAN WELL rather than assuming a figure. Overload protection is common to the adapter and trips at 120%~200% of rated output power in hiccup mode, recovering automatically once the fault is removed.
When you load one rail heavily the other rails can drift slightly. MEAN WELL publishes a ±15% cross regulation figure for the GP50A series, measured with the load swept between 20% and full rated load, while load regulation on a single rail is ±5.0%. If your circuit is sensitive to rail interaction, verify the actual deviation under your own load profile rather than assuming each rail is independent.
The standard plug is R1B, a DIN 5-pin male connector, with pin 1 and 2 as COM, pin 3 as +5VDC, pin 4 as -Vout and pin 5 as +Vout. The output cable is UL2464 18AWG*5C, 1000+150/-0mm. The only alternative in the datasheet is a stripped and tinned lead set, which is a custom item with L 70mm and L1 10mm as standard, supplied with an FG wire.
No. GP50A is an industrial ITE adapter certified to the 62368-1 family with no patient-protection rating. For equipment with patient contact use a 60601-1 certified adapter with 2xMOPP isolation from the MEAN WELL GSM medical series. As with any component supply, EMC and safety of the complete system must be confirmed in the end device.
Every triple-output combination in the GP50A family.
Mobile:+8615397378162
Tel:+86-577-89887719
Whatsapp:+8615397378162
Email:info@ledluxhub.com
Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA