info@ledluxhub.com+8615397378162
Home     Products     MEAN WELL     Medical Grade Power Supplies       MEAN WELL Power Supply GST60A Series Rel
  • MEAN WELL Power Supply GST60A Series Reliable Green Industrial Adaptor - Image 1

MEAN WELL Power Supply GST60A Series Reliable Green Industrial Adaptor

  • Product Item : GST60A series
  • Category:Medical Grade Power Supplies
  • Wattage: 60W
  • Input Voltage: 90 ~ 264VAC
  • Current Range: 1.25 ~ 6.0A
  • DC Voltage: 5 ~ 48V
  • Product description:GST60A is a highly reliable, 60W desktop style single-output green adaptor series.
  • INQUIRY   EMAIL

GST60A Series - 60W Desktop Adapter, Class I, 3-Pole IEC320-C14 Inlet, 8 Output Models 5V ~ 48VDC, Level VI

125 x 50 x 31.5mm | 90~264VAC Input | 8 Output Models 5V ~ 48VDC | 30W~60W | 3-Pole IEC320-C14 AC Inlet | Class I with Protective Earth | LPS Passed | No-Load <0.075W | Efficiency Level VI | Leakage 0.75mA Max | -30~+70C | 3-Year Warranty

In Stock 3-Year Warranty Efficiency Level VI Class I IEC320-C14 Inlet LPS Passed EMC Class B 60W Max

Key Performance at a Glance

60W
Rated Power
91%
Peak Efficiency
8
Output Voltages
<0.075W
No-Load Power
Class I
Protection Class
C14
AC Inlet

Product Overview

The MEAN WELL GST60A series is a high-reliability 60W AC-DC desktop single-output green adapter built into a fully enclosed plastic housing. It connects to mains through a 3-pole IEC320-C14 inlet and is a Class I power supply with protective earth. Input range is a universal 90~264VAC, and the series covers eight output voltages from 5V to 48VDC, serving consumer electronic devices, telecom equipment, office equipment and industrial equipment.

Because the input is 3-pole, the chassis is bonded to earth and the unit has passed the LPS (limited power source) test. Withstand voltage is 3KVAC input-to-output, 2KVAC input-to-FG and 0.5KVAC output-to-FG, with insulation resistance of 100M Ohms minimum at 500VDC. The 94V-0 flame-retardant enclosure is fully sealed, so no live part is exposed in normal operation. Note that this is an ITE product: maximum leakage current is 0.75mA at 240VAC, so for patient-contact medical equipment choose a 60601-1 certified adapter from the GSM series instead.

Efficiency reaches 91% on the 48V model with no-load power consumption below 0.075W across the series, meeting Efficiency Level VI and complying with USA EISA 2007/DoE, Canada NRCan, Korea K-MEPS, AU/NZ MEPS, EU ErP and CoC Version 5. Safety approvals cover UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, CCC GB4943.1, PSE J62368-1, AS/NZS 62368.1, BIS IS13252, KC K60950-1 and EAC TP TC 004, with conducted and radiated emissions held to Class B limits.

The standard DC output plug is the P1J (5.5 x 2.1 x 11mm tuning fork, center positive). In the standard version the negative output is not connected to AC FG. Tuning fork, barrel, lock, min. pin, center pin and DIN style plugs can be fitted at the factory, and quick-change DC plug adapters are sold separately with no MOQ. Protections cover short circuit, overload (105%~150% of rated power, hiccup mode with auto-recovery), over voltage (trip window specified per model, shutdown output and restart to recover) and over temperature (shutdown output, restart after the unit cools down). The 125 x 50 x 31.5mm adapter weighs 305g, operates from -30C to +70C and is backed by a 3-year warranty.

Product Images

GST60A series 60W desktop adapter with IEC320-C14 inlet product image
GST60A series optional DC output plug styles
GST60A series desktop adapter dimension drawing

Technical Specifications

Output ratings for all eight GST60A models. All values measured at 230VAC input, rated load, 25C / 70%RH unless otherwise noted.

Model Output Voltage Rated Current Current Range Rated Power (Max) Efficiency (Typ.)
GST60A05-P1J 5V 6A 0 ~ 6A 30W 85.5%
GST60A07-P1J 7.5V 6A 0 ~ 6A 45W 88.5%
GST60A09-P1J 9V 6A 0 ~ 6A 54W 89%
GST60A12-P1J 12V 5A 0 ~ 5A 60W 89.5%
GST60A15-P1J 15V 4A 0 ~ 4A 60W 89.5%
GST60A18-P1J 18V 3.33A 0 ~ 3.33A 60W 89.5%
GST60A24-P1J 24V 2.5A 0 ~ 2.5A 60W 90.5%
GST60A48-P1J 48V 1.25A 0 ~ 1.25A 60W 91%
Model Ripple & Noise (Max) Voltage Tolerance Line Regulation Load Regulation OVP Trip Point
GST60A05-P1J 120mVp-p ±5.0% ±1.0% ±5.0% 5.2 ~ 6.8V
GST60A07-P1J 120mVp-p ±5.0% ±1.0% ±5.0% 7.8 ~ 10.2V
GST60A09-P1J 120mVp-p ±5.0% ±1.0% ±5.0% 9.4 ~ 12.2V
GST60A12-P1J 120mVp-p ±3.0% ±1.0% ±3.0% 12.6 ~ 16.2V
GST60A15-P1J 120mVp-p ±3.0% ±1.0% ±3.0% 15.7 ~ 20.3V
GST60A18-P1J 150mVp-p ±3.0% ±1.0% ±3.0% 18.9 ~ 24.3V
GST60A24-P1J 150mVp-p ±3.0% ±1.0% ±3.0% 25.2 ~ 32.4V
GST60A48-P1J 200mVp-p ±2.5% ±1.0% ±2.5% 50.4 ~ 64.8V

Overload protection is specified once for the whole series: it trips at 105%~150% of rated output power in hiccup mode and recovers automatically once the fault condition is removed. Over-voltage protection is specified per model, with the trip window listed in the OVP column above; the output shuts down and recovers on restart. Both are listed in full in the Input & Protection table below.

DC Plug & Connector Options

Style Type Model OD x ID x L (mm) Quick-Change Adapter
Standard Tuning fork, center positive P1J 5.5 x 2.1 x 11.0 Available (7.5A max)
Tuning Fork Straight P1I / P1L / P1M 5.5 x 2.1 x 9.5 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Available (7.5A max)
Tuning Fork Right-angled P1IR / P1JR / P1LR / P1MR 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Available (7.5A max)
Barrel Straight P2I / P2J / P2L / P2M 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Not available
Barrel Right-angled P2IR / P2JR / P2LR / P2MR 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Not available
Lock (SWITCHCRAFT original or equivalent) Floating locking P2S (S761K) / P2K (761K) 5.53 x 2.03 x 12.06 / 5.53 x 2.54 x 12.06 Not available
Lock (SWITCHCRAFT original or equivalent) - P2C (S760K) / P2D (760K) 5.53 x 2.03 x 9.52 / 5.53 x 2.54 x 9.52 Not available
Min. Pin (EIAJ equivalent) - P3A / P3B / P3C 2.35 x 0.7 x 11.0 / 4.0 x 1.7 x 11.0 / 4.75 x 1.7 x 11.0 Available (5A max)
Center Pin (EIAJ equivalent) - P4A / P4B / P4C 5.5 x 3.4 x 11.0 (pin 1.0) / 6.5 x 4.4 x 11.0 (pin 1.4) / 7.4 x 5.1 x 11.0 (pin 0.6) Available (7.5A max)
Min. DIN 3 Pin with Lock (male) KYCON KPPX-3P equivalent R6B - Available (7.5A max)
Min. DIN 4 Pin with Lock (male) KYCON KPPX-4P equivalent R7B - Available (7.5A max)
Min. DIN 4 Pin with Lock (female) KYCON KPJX-CM-4S equivalent R7BF - Not available
DIN 5 Pin (male) - R1B - Available (7.5A max)
Stripped & tinned leads Custom Custom (MOQ required) Red +Vo / Black -Vo | standard L: 25mm, L1: 5mm Not available

Note: quick-change adapter availability is listed per plug family as published in the MEAN WELL datasheet, and the standard P1J plug belongs to the tuning fork family. Custom plug versions require a minimum order quantity; wire colors on stripped-lead versions are for reference only. In the standard P1J version the negative output (-V) is not connected to AC FG - tell us if your end device expects the output referenced to earth.

Input & Protection (All Models)

AC Input Range 90~264VAC | 47~63Hz
AC Inlet 3-pole IEC320-C14 inlet | Class I construction with protective earth
AC Current (Typ.) 1.4A / 115VAC | 1A / 230VAC
Inrush Current (Max.) Cold start 35A / 115VAC | 65A / 230VAC
Leakage Current (Max.) 0.75mA / 240VAC
Efficiency 85.5%~91% depending on model | Efficiency Level VI for the whole series | Complies with USA EISA 2007/DoE, Canada NRCan, Korea K-MEPS, AU/NZ MEPS, EU ErP and CoC Version 5
No-Load Power Consumption <0.075W
Set Up / Rise Time 1000ms, 50ms / 230VAC | 1000ms, 50ms / 115VAC at full load
Hold Up Time (Typ.) 50ms / 230VAC | 15ms / 115VAC at full load
Overload Protection 105%~150% of rated output power | Hiccup mode, auto-recovery after the fault condition is removed
Over-Voltage Protection Trip window is specified per model - see the OVP column in the output regulation table | Output shutdown, restart to recover
Over-Temperature Protection Output shutdown, restart to recover after the unit cools down
Operating Temp / Humidity -30~+70C (refer to derating curve) | 20~90% RH non-condensing
Storage Temp / Humidity -40~+85C | 10~95% RH non-condensing
Temp Coefficient ±0.03%/C (0~50C)
Vibration 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis
DC Output Cable UL2464 16AWG 1000±50mm for 5~9V models | UL1185 16AWG 1000±50mm for 12~15V models | UL1185 16AWG 1500±50mm for 18V | UL1185 18AWG 1800±50mm for 24~48V models
MTBF 3620.0K hrs min. Telcordia SR-332 (Bellcore) | 709.7K hrs min. MIL-HDBK-217F (25C)
Dimensions / Packing 125 x 50 x 31.5mm (L*W*H) | 0.305Kg; 40pcs / 13.02Kg / 1.04CUFT per carton
Enclosure Model / Indicator Enclosure model GS60A | Power-on LED indicator on the housing
LPS Rating Passed LPS (limited power source) test

Safety Standards & Certifications

ITE Safety Standards UL62368-1; CSA C22.2 No.62368-1; TUV BS EN/EN62368-1; BSMI CNS15598-1; CCC GB4943.1; PSE J62368-1; AS/NZS 62368.1; BIS IS13252; KC K60950-1; EAC TP TC 004
Protection Class Class I (protective earth bonded through the 3-pole IEC320-C14 inlet)
Withstand Voltage I/P-O/P: 3KVAC | I/P-FG: 2KVAC | O/P-FG: 0.5KVAC
Insulation Resistance I/P-O/P: 100M Ohms / 500VDC / 25C / 70% RH
EMC Emission Conducted emission: BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B), CNS15936, GB17625.1, EAC TP TC 020, MSIP KN32 - Class B | Radiated emission: same standards, Class B | Harmonic current: BS EN/EN61000-3-2, GB9254 Class A | Voltage flicker: BS EN/EN61000-3-3
EMC Immunity BS EN/EN55035 | ESD BS EN/EN61000-4-2 Level 4 (15KV air) / Level 4 (8KV contact) | RF field BS EN/EN61000-4-3 Level 2, 3V/m | EFT bursts BS EN/EN61000-4-4 Level 2, 1KV | Surge BS EN/EN61000-4-5 Level 3, 1KV line-line / 2KV line-FG | Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V | Magnetic field BS EN/EN61000-4-8 Level 2, 3A/m | Voltage dips and interruption BS EN/EN61000-4-11
Housing / Protections 94V-0 flame-retardant fully enclosed plastic housing | Protections: short circuit / overload / over voltage / over temperature
Warranty 3 years

Key Features

Class I with 3-Pole IEC320-C14 Inlet
The GST60A connects through a standard 3-pole IEC320-C14 mains inlet and bonds the protective earth, so it can be used in installations that require a grounded chassis. Withstand voltage is 3KVAC I/P-O/P, 2KVAC I/P-FG and 0.5KVAC O/P-FG.
LPS Passed, Fully Enclosed Housing
The series has passed the LPS (limited power source) test and uses a 94V-0 flame-retardant fully enclosed plastic housing, with no live part exposed in normal operation.
Eight Voltages from 5V to 48VDC
One 60W desktop platform covers 5V / 7.5V / 9V / 12V / 15V / 18V / 24V / 48VDC. Output current is capped at 6A on the three lowest voltages, so the 5V model is rated 30W, the 7.5V model 45W and the 9V model 54W, while the 12V through 48V models are rated 60W maximum.
Level VI Efficiency, No-Load Below 0.075W
Efficiency up to 91% with no-load power below 0.075W. The whole series meets Efficiency Level VI and complies with USA EISA 2007/DoE, Canada NRCan, Korea K-MEPS, AU/NZ MEPS, EU ErP and CoC Version 5.
Flexible DC Plug Options
Standard P1J 5.5 x 2.1 x 11mm tuning fork plug. Tuning fork, barrel, lock, min. pin, center pin, DIN and stripped-lead versions can be factory fitted; quick-change DC plug adapters are sold separately with no MOQ.
Desktop Housing, Wide Temperature Range
94V-0 flame-retardant enclosure with an IEC320-C14 inlet and a power-on LED indicator. 125 x 50 x 31.5mm, 0.305Kg, operating range -30C to +70C, backed by a 3-year warranty.

Frequently Asked Questions

Which safety standards and certifications does the GST60A series carry?

GST60A is certified to UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, CCC GB4943.1, PSE J62368-1, AS/NZS 62368.1, BIS IS13252, KC K60950-1 and EAC TP TC 004. Conducted and radiated emissions meet Class B limits to BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22, CAN ICES-3(B)/NMB-3(B), CNS15936, GB17625.1, EAC TP TC 020 and MSIP KN32. ESD immunity is Level 4 at 15KV air and Level 4 at 8KV contact.

Is the GST60A a Class I or a Class II power supply?

GST60A is a Class I power supply. It connects through a 3-pole IEC320-C14 inlet and bonds the protective earth to the chassis, which is why more than two conductors are present on the mains side. It has passed the LPS (limited power source) test and uses a 94V-0 flame-retardant fully enclosed plastic housing.

Is the GST60A really 60W on every output voltage?

No. Output current is capped at 6A on the three lowest voltages, so the 5V model is rated 30W maximum, the 7.5V model 45W and the 9V model 54W. The 12V, 15V, 18V, 24V and 48V models are all rated 60W maximum. All eight share the same 125 x 50 x 31.5mm housing and the same 90~264VAC input range. There is no 28V model in this series - the line-up goes from 24V straight to 48V.

Can I change the DC output plug of a GST60A adapter?

The standard plug is P1J, a 5.5 x 2.1 x 11mm tuning fork type with center positive polarity. MEAN WELL can fit other plug styles such as tuning fork, barrel, lock, min. pin, center pin and DIN connectors at the factory subject to a minimum order quantity. For small quantities, quick-change DC plug adapters are available separately and require no MOQ.

Is the DC output connected to AC ground?

In the standard P1J version the negative output (-V) is not connected to AC FG, even though the mains input is Class I and the chassis is earthed. If your end device expects the output referenced to earth, tell us the grounding scheme when ordering so we can confirm the correct build.

Can I use the GST60A for a medical device?

No. GST60A is an ITE product certified to the 62368-1 safety standard with a maximum leakage current of 0.75mA at 240VAC. For equipment with patient contact, use a 60601-1 certified adapter from the MEAN WELL GSM medical series instead, which provides 2xMOPP isolation and touch current below 50uA. The adapter is in any case a component intended to be built into end equipment, so EMC and safety of the complete system must be confirmed with the finished device.

How do the protection circuits of the GST60A behave?

Overload protection trips at 105%~150% of rated output power and runs in hiccup mode, recovering automatically once the fault is removed. Over-voltage protection has a trip window specified per model (for example 5.2~6.8V on the 5V model) and shuts the output down until the unit is restarted. Over-temperature protection also shuts the output down and requires a restart after the unit has cooled. Short circuit protection recovers automatically.

Related Products

Explore every output voltage in the GST60A family.

Available Models

  • GST60A05-P1J - 5VDC / 6A (30W max) / ripple <120mVp-p / ±5.0% accuracy / 85.5% efficiency / Level VI / P1J standard plug
  • GST60A07-P1J - 7.5VDC / 6A (45W max) / ripple <120mVp-p / ±5.0% accuracy / 88.5% efficiency / Level VI / P1J standard plug
  • GST60A09-P1J - 9VDC / 6A (54W max) / ripple <120mVp-p / ±5.0% accuracy / 89% efficiency / Level VI / P1J standard plug
  • GST60A12-P1J - 12VDC / 5A (60W max) / ripple <120mVp-p / ±3.0% accuracy / 89.5% efficiency / Level VI / P1J standard plug
  • GST60A15-P1J - 15VDC / 4A (60W max) / ripple <120mVp-p / ±3.0% accuracy / 89.5% efficiency / Level VI / P1J standard plug
  • GST60A18-P1J - 18VDC / 3.33A (60W max) / ripple <150mVp-p / ±3.0% accuracy / 89.5% efficiency / Level VI / P1J standard plug
  • GST60A24-P1J - 24VDC / 2.5A (60W max) / ripple <150mVp-p / ±3.0% accuracy / 90.5% efficiency / Level VI / P1J standard plug
  • GST60A48-P1J - 48VDC / 1.25A (60W max) / ripple <200mVp-p / ±2.5% accuracy / 91% efficiency / Level VI / P1J standard plug

INQUIRY US