info@ledluxhub.com+8615397378162
Home     Products     MEAN WELL     LED Driver       MEAN WELL Power Supply GSM18U Series Rel
  • MEAN WELL Power Supply GSM18U Series Reliable Green Medical Adaptor - Image 1

MEAN WELL Power Supply GSM18U Series Reliable Green Medical Adaptor

  • Product Item : GSM18U series
  • Category:LED Driver
  • Wattage: 315W
  • Input Voltage: 100 ~ 305VAC or 142 ~ 431VDC
  • Output Current: 1400 ~ 5600mA
  • Output Voltage: 65 ~ 340V
  • Product description:XLG-320-DA2 series is a 315W LED AC/DC driver featuring the constant power mode with DALl-2 dimming function.
  • INQUIRY   EMAIL

GSM18U Series - 18W Medical Grade Wall-Mount Adapter, Fixed USA 2-Pin Plug, Class II, 2xMOPP, Level VI

79 x 54 x 33mm | 80~264VAC Input (113~370VDC) | 8 Output Models 5V ~ 48VDC | 15W~18W | Fixed USA 2-Pole Plug (No FG) | Class II Double Insulated | 2xMOPP | Touch Current <50uA | No-Load <0.1W | Efficiency Level VI (Level V for 5~9V Models) | -25~+60C | 3-Year Warranty

In Stock 3-Year Warranty Medical Grade 2xMOPP Class II Efficiency Level VI Leakage <50uA 18W Max

Key Performance at a Glance

18W
Rated Power
88%
Peak Efficiency
8
Output Voltages
<50uA
Touch Current
<0.1W
No-Load Power
2xMOPP
Isolation

Product Overview

The MEAN WELL GSM18U series is a high-reliability 18W AC-DC wall-mount single-output green medical adapter with a fixed 2-pole USA plug (no FG). It accepts 80~264VAC input and provides eight output voltages from 5V to 48VDC, covering the supply needs of small medical equipment such as blood glucose meters, blood pressure monitors, nebulizers, inhalers and other portable medical devices.

The circuit is designed to international medical standards with 2xMOPP (two Means Of Patient Protection) primary-to-secondary isolation and an ultra-low touch current below 50uA at 264VAC, making it suitable for medical devices with direct patient contact. Withstand voltage is 4KVAC input-to-output and insulation resistance is 100M Ohms minimum. The 94V-0 flame-retardant plastic enclosure provides double insulation, so the adapter is a Class II construction that needs no functional earth connection.

Efficiency reaches 88% with no-load power consumption below 0.1W, meeting Efficiency Level VI (Level V for the 5V, 7.5V and 9V models) and complying with USA EISA 2007/DoE and Canada NRCan. Medical safety approvals include ANSI/AAMI ES60601-1/-1-11, IEC 60601-1/-1-11, CAN/CSA C22.2 No. 60601-1/-1-11 and EAC TP TC 004, with conducted and radiated emissions to FCC Part 15 / CISPR22 Class B.

The standard DC output plug is the P1J (5.5 x 2.1 x 11mm tuning fork, center positive). Tuning fork, barrel, lock, min. pin, center pin and DIN style plugs can be fitted at the factory on request, and quick-change DC plug adapters are available separately so the same adapter can serve devices with different sockets. Protections cover short circuit, overload (105%~170%, hiccup mode with auto-recovery) and over voltage (output shutdown, restart to recover). The adapter operates from -25C to +60C and is backed by a 3-year warranty.

Product Images

GSM18U series 18W medical wall-mount adapter product image
GSM18U series optional DC output plug styles
GSM18U series medical adapter dimension drawing

Technical Specifications

Output ratings for all eight GSM18U models. All values measured at 115VAC input, rated load, 25C / 70%RH unless otherwise noted.

Model Output Voltage Rated Current Current Range Rated Power (Max) Efficiency (Typ.)
GSM18U05-P1J 5V 3A 0 ~ 3A 15W 80%
GSM18U07-P1J 7.5V 2A 0 ~ 2A 15W 83%
GSM18U09-P1J 9V 2A 0 ~ 2A 18W 84%
GSM18U12-P1J 12V 1.5A 0 ~ 1.5A 18W 86%
GSM18U15-P1J 15V 1.2A 0 ~ 1.2A 18W 87%
GSM18U18-P1J 18V 1A 0 ~ 1A 18W 87%
GSM18U24-P1J 24V 0.75A 0 ~ 0.75A 18W 87%
GSM18U48-P1J 48V 0.375A 0 ~ 0.375A 18W 88%
Model Ripple & Noise (Max) Voltage Tolerance Line Regulation Load Regulation Over-Voltage Protection
GSM18U05-P1J 60mVp-p ±5.0% ±1.0% ±5.0% 5.25 ~ 7.5V
GSM18U07-P1J 80mVp-p ±5.0% ±1.0% ±5.0% 7.88 ~ 10.13V
GSM18U09-P1J 80mVp-p ±5.0% ±1.0% ±5.0% 9.45 ~ 12.6V
GSM18U12-P1J 120mVp-p ±3.0% ±1.0% ±3.0% 12.6 ~ 17.2V
GSM18U15-P1J 120mVp-p ±3.0% ±1.0% ±3.0% 15.75 ~ 20.25V
GSM18U18-P1J 150mVp-p ±3.0% ±1.0% ±3.0% 18.9 ~ 24.3V
GSM18U24-P1J 180mVp-p ±2.0% ±1.0% ±2.0% 25.2 ~ 32.4V
GSM18U48-P1J 240mVp-p ±2.0% ±1.0% ±2.0% 50.4 ~ 64.8V

DC Plug & Connector Options

Style Type Model OD x ID x L (mm) Quick-Change Adapter
Standard Tuning fork, center positive P1J 5.5 x 2.1 x 11.0 Available (7.5A max)
Tuning Fork Straight P1I / P1L / P1M 5.5 x 2.1 x 9.5 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Available (7.5A max)
Tuning Fork Right-angled P1IR / P1JR / P1LR / P1MR 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Available (7.5A max)
Barrel Straight P2I / P2J / P2L / P2M 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Not available
Barrel Right-angled P2IR / P2JR / P2LR / P2MR 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Not available
Lock (SWITCHCRAFT original or equivalent) Floating locking P2S (S761K) / P2K (761K) 5.53 x 2.03 x 12.06 / 5.53 x 2.54 x 12.06 Not available
Lock (SWITCHCRAFT original or equivalent) - P2C (S760K) / P2D (760K) 5.53 x 2.03 x 9.52 / 5.53 x 2.54 x 9.52 Not available
Min. Pin (EIAJ equivalent) - P3A / P3B / P3C 2.35 x 0.7 x 11.0 / 4.0 x 1.7 x 11.0 / 4.75 x 1.7 x 11.0 Available (5A max)
Center Pin (EIAJ equivalent) - P4A / P4B / P4C 5.5 x 3.4 x 11.0 (pin 1.0) / 6.5 x 4.4 x 11.0 (pin 1.4) / 7.4 x 5.1 x 11.0 (pin 0.6) Available (7.5A max)
Min. DIN 3 Pin with Lock (male) KYCON KPPX-3P equivalent R6B - Available (7.5A max)
Min. DIN 4 Pin with Lock (male) KYCON KPPX-4P equivalent R7B - Available (7.5A max)
Min. DIN 4 Pin with Lock (female) KYCON KPJX-CM-4S equivalent R7BF - Not available
DIN 5 Pin (male) - R1B - Available (7.5A max)
Stripped & tinned leads Custom Custom (MOQ required) Red +Vo / Black -Vo | standard L: 25mm, L1: 5mm Not available

Note: quick-change adapter availability is listed per plug family as published in the MEAN WELL datasheet, and the standard P1J plug belongs to the tuning fork family. Custom plug versions require a minimum order quantity; wire colors on stripped-lead versions are for reference only.

Input & Protection (All Models)

AC Input Range 80~264VAC | 113~370VDC | 47~63Hz
AC Current (Typ.) 0.5A / 115VAC | 0.25A / 230VAC
Inrush Current (Typ.) 55A / 230VAC | 30A / 115VAC
Leakage Current (Max.) Touch current <50uA / 264VAC
Efficiency 80%~88% depending on model | Efficiency Level VI (Level V for the 5V / 7.5V / 9V models) | Complies with USA EISA 2007/DoE and Canada NRCan
No-Load Power Consumption <0.1W
Set Up / Rise Time 500ms, 30ms / 230VAC | 1000ms, 30ms / 115VAC at full load
Hold Up Time (Typ.) 16ms / 230VAC | 16ms / 115VAC at full load
Overload Protection 105%~170% of rated output power | Hiccup mode, auto-recovery after fault condition is removed
Over-Voltage Protection Shuts down output, restart to recover (per-model trip window listed in the tables above)
Operating Temp / Humidity -25~+60C (refer to derating curve) | 20~90% RH non-condensing
Storage Temp / Humidity -40~+85C | 10~95% RH non-condensing
Temp Coefficient ±0.03%/C (0~40C)
Vibration 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis
DC Output Cable UL1185 16AWG 1200±50mm for 5~9V models | UL1185 18AWG 1800±50mm for 12~48V models
MTBF 3889.1K hrs min. Telcordia SR-332 (Bellcore) | 794.6K hrs min. MIL-HDBK-217F (25C)
Dimensions / Packing 79 x 54 x 33mm (L*W*H) | 185g; 60pcs / 12.1Kg / carton

Safety Standards & Certifications

Medical Safety Standards IEC 60601-1:2005+A1+A2; IEC 60601-1-11:2015+A1; ANSI/AAMI ES60601-1:2005+A2; ANSI/AAMI HA60601-1-11+A1; CAN/CSA C22.2 No. 60601-1:2014+A2; CSA C22.2 No. 60601-1-11:2015+A1; EAC TP TC 004
Insulation / MOPP Primary to secondary: 2xMOPP (two Means Of Patient Protection)
Withstand Voltage I/P-O/P: 4KVAC
Insulation Resistance I/P-O/P: 100M Ohms / 500VDC / 25C / 70% RH
EMC Emission Conducted emission: FCC Part 15 / CISPR22 Class B | Radiated emission: FCC Part 15 / CISPR22 Class B
Housing / Protection Class 94V-0 flame-retardant plastic enclosure | Class II double insulated | Protections: short circuit / overload / over voltage
Warranty 3 years

Key Features

Medical Grade 2xMOPP Isolation
Approved to ANSI/AAMI ES60601-1/-1-11 and IEC 60601-1/-1-11 with 2xMOPP primary-to-secondary isolation. Withstand voltage 4KVAC input-to-output, insulation resistance 100M Ohms minimum.
Ultra-Low Leakage Current
Touch current below 50uA at 264VAC makes GSM18U suitable for medical equipment in contact with the patient. Confirm the applied-part classification against your end-device risk assessment.
Eight Voltages from 5V to 48VDC
One 18W wall-mount platform covers 5V / 7.5V / 9V / 12V / 15V / 18V / 24V / 48VDC. The 5V and 7.5V models are rated 15W maximum, the other six are rated 18W maximum.
Level VI Efficiency, No-Load Below 0.1W
Efficiency up to 88% with no-load power below 0.1W, meeting Efficiency Level VI (Level V for 5V / 7.5V / 9V) and complying with USA EISA 2007/DoE and Canada NRCan.
Flexible DC Plug Options
Standard P1J 5.5 x 2.1 x 11mm tuning fork plug. Tuning fork, barrel, lock, min. pin, center pin, DIN and stripped-lead versions can be factory fitted; quick-change DC plug adapters are sold separately with no MOQ.
Compact Class II Housing, Wide Temperature
94V-0 flame-retardant plastic enclosure with double insulation and no functional earth required. 79 x 54 x 33mm, 185g, operating range -25C to +60C, backed by a 3-year warranty.

Frequently Asked Questions

Which medical safety standards does the GSM18U series meet?

GSM18U complies with IEC 60601-1:2005+A1+A2, IEC 60601-1-11:2015+A1, ANSI/AAMI ES60601-1:2005+A2, ANSI/AAMI HA60601-1-11+A1, CAN/CSA C22.2 No. 60601-1:2014+A2, CSA C22.2 No. 60601-1-11:2015+A1 and EAC TP TC 004. Conducted and radiated emissions meet FCC Part 15 / CISPR22 Class B.

What does 2xMOPP mean and why does it matter?

MOPP stands for Means Of Patient Protection. GSM18U provides 2xMOPP isolation between the primary and secondary side, verified with a 4KVAC withstand voltage test and 100M Ohms insulation resistance. Higher MOPP ratings allow the supply to be used in equipment whose applied parts are in contact with the patient, subject to the end-device risk assessment.

Is the GSM18U a Class II adapter, and what does "No FG" mean?

Yes. GSM18U uses a fixed 2-pole USA plug without a functional earth (FG) pin and a 94V-0 flame-retardant plastic enclosure that provides double insulation. Because the construction is Class II, no protective earth connection is required, which simplifies wiring in portable and handheld medical devices.

Is the GSM18U really 18W on every output voltage?

No. The 5V (3A) and 7.5V (2A) models are rated 15W maximum output power. The 9V, 12V, 15V, 18V, 24V and 48V models are rated 18W maximum. All eight share the same 79 x 54 x 33mm housing and the same 80~264VAC input range.

Can I change the DC output plug of a GSM18U adapter?

The standard plug is P1J, a 5.5 x 2.1 x 11mm tuning fork type with center positive polarity. MEAN WELL can fit other plug styles such as tuning fork, barrel, lock, min. pin, center pin and DIN connectors at the factory subject to a minimum order quantity. For small quantities, quick-change DC plug adapters are available separately and require no MOQ.

Does the adapter need any external protection circuit?

GSM18U already includes short-circuit, overload (105%~170% of rated power, hiccup mode with auto-recovery) and over-voltage protection (output shutdown, restart to recover). Note that the adapter is a component intended to be built into end equipment, so the EMC performance of the complete system must be confirmed with the finished device.

Related Products

Explore every output voltage in the GSM18U family.

Available Models

  • GSM18U05-P1J - 5VDC / 3A (15W max) / ripple <60mVp-p / ±5.0% accuracy / 80% efficiency / Level V / P1J standard plug
  • GSM18U07-P1J - 7.5VDC / 2A (15W max) / ripple <80mVp-p / ±5.0% accuracy / 83% efficiency / Level V / P1J standard plug
  • GSM18U09-P1J - 9VDC / 2A (18W max) / ripple <80mVp-p / ±5.0% accuracy / 84% efficiency / Level V / P1J standard plug
  • GSM18U12-P1J - 12VDC / 1.5A (18W max) / ripple <120mVp-p / ±3.0% accuracy / 86% efficiency / Level VI / P1J standard plug
  • GSM18U15-P1J - 15VDC / 1.2A (18W max) / ripple <120mVp-p / ±3.0% accuracy / 87% efficiency / Level VI / P1J standard plug
  • GSM18U18-P1J - 18VDC / 1A (18W max) / ripple <150mVp-p / ±3.0% accuracy / 87% efficiency / Level VI / P1J standard plug
  • GSM18U24-P1J - 24VDC / 0.75A (18W max) / ripple <180mVp-p / ±2.0% accuracy / 87% efficiency / Level VI / P1J standard plug
  • GSM18U48-P1J - 48VDC / 0.375A (18W max) / ripple <240mVp-p / ±2.0% accuracy / 88% efficiency / Level VI / P1J standard plug

GSM18U Series - 18W Medical Grade Wall-Mount Adapter, Fixed USA 2-Pin Plug, Class II, 2xMOPP, Level VI

79 x 54 x 33mm | 80~264VAC Input (113~370VDC) | 8 Output Models 5V ~ 48VDC | 15W~18W | Fixed USA 2-Pole Plug (No FG) | Class II Double Insulated | 2xMOPP | Touch Current <50uA | No-Load <0.1W | Efficiency Level VI (Level V for 5~9V Models) | -25~+60C | 3-Year Warranty

In Stock 3-Year Warranty Medical Grade 2xMOPP Class II Efficiency Level VI Leakage <50uA 18W Max

Key Performance at a Glance

18W
Rated Power
88%
Peak Efficiency
8
Output Voltages
<50uA
Touch Current
<0.1W
No-Load Power
2xMOPP
Isolation

Product Overview

The MEAN WELL GSM18U series is a high-reliability 18W AC-DC wall-mount single-output green medical adapter with a fixed 2-pole USA plug (no FG). It accepts 80~264VAC input and provides eight output voltages from 5V to 48VDC, covering the supply needs of small medical equipment such as blood glucose meters, blood pressure monitors, nebulizers, inhalers and other portable medical devices.

The circuit is designed to international medical standards with 2xMOPP (two Means Of Patient Protection) primary-to-secondary isolation and an ultra-low touch current below 50uA at 264VAC, making it suitable for medical devices with direct patient contact. Withstand voltage is 4KVAC input-to-output and insulation resistance is 100M Ohms minimum. The 94V-0 flame-retardant plastic enclosure provides double insulation, so the adapter is a Class II construction that needs no functional earth connection.

Efficiency reaches 88% with no-load power consumption below 0.1W, meeting Efficiency Level VI (Level V for the 5V, 7.5V and 9V models) and complying with USA EISA 2007/DoE and Canada NRCan. Medical safety approvals include ANSI/AAMI ES60601-1/-1-11, IEC 60601-1/-1-11, CAN/CSA C22.2 No. 60601-1/-1-11 and EAC TP TC 004, with conducted and radiated emissions to FCC Part 15 / CISPR22 Class B.

The standard DC output plug is the P1J (5.5 x 2.1 x 11mm tuning fork, center positive). Tuning fork, barrel, lock, min. pin, center pin and DIN style plugs can be fitted at the factory on request, and quick-change DC plug adapters are available separately so the same adapter can serve devices with different sockets. Protections cover short circuit, overload (105%~170%, hiccup mode with auto-recovery) and over voltage (output shutdown, restart to recover). The adapter operates from -25C to +60C and is backed by a 3-year warranty.

Product Images

GSM18U series 18W medical wall-mount adapter product image
GSM18U series optional DC output plug styles
GSM18U series medical adapter dimension drawing

Technical Specifications

Output ratings for all eight GSM18U models. All values measured at 115VAC input, rated load, 25C / 70%RH unless otherwise noted.

Model Output Voltage Rated Current Current Range Rated Power (Max) Efficiency (Typ.)
GSM18U05-P1J 5V 3A 0 ~ 3A 15W 80%
GSM18U07-P1J 7.5V 2A 0 ~ 2A 15W 83%
GSM18U09-P1J 9V 2A 0 ~ 2A 18W 84%
GSM18U12-P1J 12V 1.5A 0 ~ 1.5A 18W 86%
GSM18U15-P1J 15V 1.2A 0 ~ 1.2A 18W 87%
GSM18U18-P1J 18V 1A 0 ~ 1A 18W 87%
GSM18U24-P1J 24V 0.75A 0 ~ 0.75A 18W 87%
GSM18U48-P1J 48V 0.375A 0 ~ 0.375A 18W 88%
Model Ripple & Noise (Max) Voltage Tolerance Line Regulation Load Regulation Over-Voltage Protection
GSM18U05-P1J 60mVp-p ±5.0% ±1.0% ±5.0% 5.25 ~ 7.5V
GSM18U07-P1J 80mVp-p ±5.0% ±1.0% ±5.0% 7.88 ~ 10.13V
GSM18U09-P1J 80mVp-p ±5.0% ±1.0% ±5.0% 9.45 ~ 12.6V
GSM18U12-P1J 120mVp-p ±3.0% ±1.0% ±3.0% 12.6 ~ 17.2V
GSM18U15-P1J 120mVp-p ±3.0% ±1.0% ±3.0% 15.75 ~ 20.25V
GSM18U18-P1J 150mVp-p ±3.0% ±1.0% ±3.0% 18.9 ~ 24.3V
GSM18U24-P1J 180mVp-p ±2.0% ±1.0% ±2.0% 25.2 ~ 32.4V
GSM18U48-P1J 240mVp-p ±2.0% ±1.0% ±2.0% 50.4 ~ 64.8V

DC Plug & Connector Options

Style Type Model OD x ID x L (mm) Quick-Change Adapter
Standard Tuning fork, center positive P1J 5.5 x 2.1 x 11.0 Available (7.5A max)
Tuning Fork Straight P1I / P1L / P1M 5.5 x 2.1 x 9.5 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Available (7.5A max)
Tuning Fork Right-angled P1IR / P1JR / P1LR / P1MR 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Available (7.5A max)
Barrel Straight P2I / P2J / P2L / P2M 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Not available
Barrel Right-angled P2IR / P2JR / P2LR / P2MR 5.5 x 2.1 x 9.5 / 5.5 x 2.1 x 11.0 / 5.5 x 2.5 x 9.5 / 5.5 x 2.5 x 11.0 Not available
Lock (SWITCHCRAFT original or equivalent) Floating locking P2S (S761K) / P2K (761K) 5.53 x 2.03 x 12.06 / 5.53 x 2.54 x 12.06 Not available
Lock (SWITCHCRAFT original or equivalent) - P2C (S760K) / P2D (760K) 5.53 x 2.03 x 9.52 / 5.53 x 2.54 x 9.52 Not available
Min. Pin (EIAJ equivalent) - P3A / P3B / P3C 2.35 x 0.7 x 11.0 / 4.0 x 1.7 x 11.0 / 4.75 x 1.7 x 11.0 Available (5A max)
Center Pin (EIAJ equivalent) - P4A / P4B / P4C 5.5 x 3.4 x 11.0 (pin 1.0) / 6.5 x 4.4 x 11.0 (pin 1.4) / 7.4 x 5.1 x 11.0 (pin 0.6) Available (7.5A max)
Min. DIN 3 Pin with Lock (male) KYCON KPPX-3P equivalent R6B - Available (7.5A max)
Min. DIN 4 Pin with Lock (male) KYCON KPPX-4P equivalent R7B - Available (7.5A max)
Min. DIN 4 Pin with Lock (female) KYCON KPJX-CM-4S equivalent R7BF - Not available
DIN 5 Pin (male) - R1B - Available (7.5A max)
Stripped & tinned leads Custom Custom (MOQ required) Red +Vo / Black -Vo | standard L: 25mm, L1: 5mm Not available

Note: quick-change adapter availability is listed per plug family as published in the MEAN WELL datasheet, and the standard P1J plug belongs to the tuning fork family. Custom plug versions require a minimum order quantity; wire colors on stripped-lead versions are for reference only.

Input & Protection (All Models)

AC Input Range 80~264VAC | 113~370VDC | 47~63Hz
AC Current (Typ.) 0.5A / 115VAC | 0.25A / 230VAC
Inrush Current (Typ.) 55A / 230VAC | 30A / 115VAC
Leakage Current (Max.) Touch current <50uA / 264VAC
Efficiency 80%~88% depending on model | Efficiency Level VI (Level V for the 5V / 7.5V / 9V models) | Complies with USA EISA 2007/DoE and Canada NRCan
No-Load Power Consumption <0.1W
Set Up / Rise Time 500ms, 30ms / 230VAC | 1000ms, 30ms / 115VAC at full load
Hold Up Time (Typ.) 16ms / 230VAC | 16ms / 115VAC at full load
Overload Protection 105%~170% of rated output power | Hiccup mode, auto-recovery after fault condition is removed
Over-Voltage Protection Shuts down output, restart to recover (per-model trip window listed in the tables above)
Operating Temp / Humidity -25~+60C (refer to derating curve) | 20~90% RH non-condensing
Storage Temp / Humidity -40~+85C | 10~95% RH non-condensing
Temp Coefficient ±0.03%/C (0~40C)
Vibration 10~500Hz, 2G, 10min/cycle, 60min each along X, Y, Z axis
DC Output Cable UL1185 16AWG 1200±50mm for 5~9V models | UL1185 18AWG 1800±50mm for 12~48V models
MTBF 3889.1K hrs min. Telcordia SR-332 (Bellcore) | 794.6K hrs min. MIL-HDBK-217F (25C)
Dimensions / Packing 79 x 54 x 33mm (L*W*H) | 185g; 60pcs / 12.1Kg / carton

Safety Standards & Certifications

Medical Safety Standards IEC 60601-1:2005+A1+A2; IEC 60601-1-11:2015+A1; ANSI/AAMI ES60601-1:2005+A2; ANSI/AAMI HA60601-1-11+A1; CAN/CSA C22.2 No. 60601-1:2014+A2; CSA C22.2 No. 60601-1-11:2015+A1; EAC TP TC 004
Insulation / MOPP Primary to secondary: 2xMOPP (two Means Of Patient Protection)
Withstand Voltage I/P-O/P: 4KVAC
Insulation Resistance I/P-O/P: 100M Ohms / 500VDC / 25C / 70% RH
EMC Emission Conducted emission: FCC Part 15 / CISPR22 Class B | Radiated emission: FCC Part 15 / CISPR22 Class B
Housing / Protection Class 94V-0 flame-retardant plastic enclosure | Class II double insulated | Protections: short circuit / overload / over voltage
Warranty 3 years

Key Features

Medical Grade 2xMOPP Isolation
Approved to ANSI/AAMI ES60601-1/-1-11 and IEC 60601-1/-1-11 with 2xMOPP primary-to-secondary isolation. Withstand voltage 4KVAC input-to-output, insulation resistance 100M Ohms minimum.
Ultra-Low Leakage Current
Touch current below 50uA at 264VAC makes GSM18U suitable for medical equipment in contact with the patient. Confirm the applied-part classification against your end-device risk assessment.
Eight Voltages from 5V to 48VDC
One 18W wall-mount platform covers 5V / 7.5V / 9V / 12V / 15V / 18V / 24V / 48VDC. The 5V and 7.5V models are rated 15W maximum, the other six are rated 18W maximum.
Level VI Efficiency, No-Load Below 0.1W
Efficiency up to 88% with no-load power below 0.1W, meeting Efficiency Level VI (Level V for 5V / 7.5V / 9V) and complying with USA EISA 2007/DoE and Canada NRCan.
Flexible DC Plug Options
Standard P1J 5.5 x 2.1 x 11mm tuning fork plug. Tuning fork, barrel, lock, min. pin, center pin, DIN and stripped-lead versions can be factory fitted; quick-change DC plug adapters are sold separately with no MOQ.
Compact Class II Housing, Wide Temperature
94V-0 flame-retardant plastic enclosure with double insulation and no functional earth required. 79 x 54 x 33mm, 185g, operating range -25C to +60C, backed by a 3-year warranty.

Frequently Asked Questions

Which medical safety standards does the GSM18U series meet?

GSM18U complies with IEC 60601-1:2005+A1+A2, IEC 60601-1-11:2015+A1, ANSI/AAMI ES60601-1:2005+A2, ANSI/AAMI HA60601-1-11+A1, CAN/CSA C22.2 No. 60601-1:2014+A2, CSA C22.2 No. 60601-1-11:2015+A1 and EAC TP TC 004. Conducted and radiated emissions meet FCC Part 15 / CISPR22 Class B.

What does 2xMOPP mean and why does it matter?

MOPP stands for Means Of Patient Protection. GSM18U provides 2xMOPP isolation between the primary and secondary side, verified with a 4KVAC withstand voltage test and 100M Ohms insulation resistance. Higher MOPP ratings allow the supply to be used in equipment whose applied parts are in contact with the patient, subject to the end-device risk assessment.

Is the GSM18U a Class II adapter, and what does "No FG" mean?

Yes. GSM18U uses a fixed 2-pole USA plug without a functional earth (FG) pin and a 94V-0 flame-retardant plastic enclosure that provides double insulation. Because the construction is Class II, no protective earth connection is required, which simplifies wiring in portable and handheld medical devices.

Is the GSM18U really 18W on every output voltage?

No. The 5V (3A) and 7.5V (2A) models are rated 15W maximum output power. The 9V, 12V, 15V, 18V, 24V and 48V models are rated 18W maximum. All eight share the same 79 x 54 x 33mm housing and the same 80~264VAC input range.

Can I change the DC output plug of a GSM18U adapter?

The standard plug is P1J, a 5.5 x 2.1 x 11mm tuning fork type with center positive polarity. MEAN WELL can fit other plug styles such as tuning fork, barrel, lock, min. pin, center pin and DIN connectors at the factory subject to a minimum order quantity. For small quantities, quick-change DC plug adapters are available separately and require no MOQ.

Does the adapter need any external protection circuit?

GSM18U already includes short-circuit, overload (105%~170% of rated power, hiccup mode with auto-recovery) and over-voltage protection (output shutdown, restart to recover). Note that the adapter is a component intended to be built into end equipment, so the EMC performance of the complete system must be confirmed with the finished device.

Related Products

Explore every output voltage in the GSM18U family.

Available Models

  • GSM18U05-P1J - 5VDC / 3A (15W max) / ripple <60mVp-p / ±5.0% accuracy / 80% efficiency / Level V / P1J standard plug
  • GSM18U07-P1J - 7.5VDC / 2A (15W max) / ripple <80mVp-p / ±5.0% accuracy / 83% efficiency / Level V / P1J standard plug
  • GSM18U09-P1J - 9VDC / 2A (18W max) / ripple <80mVp-p / ±5.0% accuracy / 84% efficiency / Level V / P1J standard plug
  • GSM18U12-P1J - 12VDC / 1.5A (18W max) / ripple <120mVp-p / ±3.0% accuracy / 86% efficiency / Level VI / P1J standard plug
  • GSM18U15-P1J - 15VDC / 1.2A (18W max) / ripple <120mVp-p / ±3.0% accuracy / 87% efficiency / Level VI / P1J standard plug
  • GSM18U18-P1J - 18VDC / 1A (18W max) / ripple <150mVp-p / ±3.0% accuracy / 87% efficiency / Level VI / P1J standard plug
  • GSM18U24-P1J - 24VDC / 0.75A (18W max) / ripple <180mVp-p / ±2.0% accuracy / 87% efficiency / Level VI / P1J standard plug
  • GSM18U48-P1J - 48VDC / 0.375A (18W max) / ripple <240mVp-p / ±2.0% accuracy / 88% efficiency / Level VI / P1J standard plug

INQUIRY US

CATEGORIES

CONTACT US

Mobile:+8615397378162

Tel:+86-577-89887719

Whatsapp:+8615397378162

Email:info@ledluxhub.com

Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA

OTHER LINK