info@ledluxhub.com+8615397378162
Home     Products     MEAN WELL     LED Driver       MEAN WELL Power Supply XLG-320-48-ABV Se
  • MEAN WELL Power Supply XLG-320-48-ABV Series Constant Current Mode LED Driver - 副本 - Image 1

MEAN WELL Power Supply XLG-320-48-ABV Series Constant Current Mode LED Driver - 副本

  • Product Item : XLG-320-48-ABV series
  • Category:LED Driver
  • Wattage: 315W
  • Input Voltage: 100 ~ 305VAC or 142 ~ 431VDC
  • Output Current: 700 ~ 4900mA
  • Output Voltage: 60 ~ 370V
  • Product description:XLG-320 series is a 315W LED AC/DC driver featuring the constant power mode.
  • INQUIRY   EMAIL

XLG-50-DA2 Series - 50W DALI-2 Constant Power LED Driver with Active PFC, Class 2, IP67

105 x 63 x 30mm Metal Housing | 90~305VAC Universal Input (127~431VDC) | L-Type 700mA / H-Type 1050mA | Constant Power 50W | Class 2 | Active PFC | Type HL (except L-Type) | IP67 | DALI-2 DT6 | >50,000hrs | 5-Year Warranty

In Stock 5-Year Warranty Constant Power 50W Max IP67 Class 2 Active PFC DALI-2 Dimming Type HL (H-Type)

Key Performance at a Glance

50W
Rated Power
90%
Peak Efficiency
2
Output Types
DALI-2
DT6 Dimming
IP67
Outdoor Rated
+85C
Max Tcase

Product Overview

The MEAN WELL XLG-50-DA2 series is a 50W AC-to-DC constant-power LED driver family with DALI-2 digital dimming, IP67 protection, Class 2 power rating, and Type HL certification for Class I, Division 2 hazardous location lighting (H-Type only). It is designed for LED street lighting, architectural lighting, bay lighting, flood lighting, stage lighting, sports lighting, and industrial lighting.

It accepts universal 90~305VAC input (127~431VDC) and provides a constant-power 50W output. Two output types are available: L-Type with default current 700mA and CC region 60~142V, and H-Type with default current 1050mA and CC region 27~56V. Output current can be adjusted via an internal potentiometer (300~700mA for L-Type, 500~1400mA for H-Type). With peak efficiency up to 90%, the driver uses a fanless design and operates at case temperatures from -40C to +85C under free air convection.

The metal enclosure carries an IP67 rating for both indoor and outdoor use. All DA2 versions support IEC 62386 DALI-2 DT6 digital dimming down to approximately 8% minimum brightness, with isolated dimming circuitry. India versions (XLG-50I-L-DA2 / XLG-50I-H-DA2) add input over-voltage protection at 320~370VAC and comply with IS 15885. No-load / standby power consumption is below 0.5W.

Protection includes short-circuit (hiccup or constant current limiting), over-temperature (de-rate to 75% then 50%, auto-recovery), and input over-voltage (320~370VAC on I-Type only, auto-recovery; withstand 440VAC for 48h). The driver complies with global lighting safety and EMC standards including UL8750 Type HL, CSA, ENEC, AS/NZS, BS EN/EN, GB/T, EAC, and IS 15885 (I-Type only), and is backed by a 5-year warranty. Note: a switch must be installed between the mains and the LED driver to meet the latest ErP regulations.

Product Images

XLG-50-DA2 series LED driver product image
XLG-50-DA2 series LED driver wiring diagram
XLG-50-DA2 series LED driver dimension diagram

Technical Specifications

Output ratings for the XLG-50-DA2 series. All values measured at 230VAC, rated current, 25C unless noted.

ModelDefault CurrentCC RegionFull Power CurrentOpen Circuit MaxAdjustment RangeIP
XLG-50-L-DA2700mA60 ~ 142V350~700mA160V300~700mAIP67
XLG-50I-L-DA2700mA60 ~ 142V350~700mA160V300~700mAIP67
XLG-50-H-DA21050mA27 ~ 56V900~1400mA60V500~1400mAIP67
XLG-50I-H-DA21050mA27 ~ 56V900~1400mA60V500~1400mAIP67

Version Types

TypeIPOutput AdjustmentDimmingInput OVPNotes
L-DA2IP67300~700mA via built-in potentiometerDALI-2 DT6 (isolated, down to ~8%)No50W / 60~142V / 700mA default; Class 2 (except L-Type)
H-DA2IP67500~1400mA via built-in potentiometerDALI-2 DT6 (isolated, down to ~8%)No50W / 27~56V / 1050mA default; Type HL
I-L-DA2IP67Same as L-DA2Same as L-DA2Yes (320~370VAC)India version; withstand 440VAC for 48h; IS 15885
I-H-DA2IP67Same as H-DA2Same as H-DA2Yes (320~370VAC)India version; withstand 440VAC for 48h; IS 15885

Input & Protection (All Versions)

Input Voltage Range90~305VAC | 127~431VDC | 47~63Hz
Active PFC / THD / AC CurrentPF>=0.97/115V, >=0.95/230V, >=0.92/277V at full load | THD<10% (@load>=50%/115VAC,230VAC; @load>=75%/277VAC) | 0.57A/115V, 0.29A/230V, 0.24A/277VAC
Inrush / Leakage / BreakerCold start 50A (twidth=350us measured at 50% Ipeak) / 230VAC per NEMA 410 | 16A breaker: 7 units (B type) / 12 units (C type) at 230VAC | <0.75mA/277VAC
Set Up / Rise Time500ms / 230VAC; 1200ms / 115VAC (DALI-2 startup timing tested with DALI controller supporting power-on function)
No-Load / Standby PowerStandard: <0.5W | I-Type: no-load <0.75W
ProtectionShort circuit: hiccup or constant current limiting, auto-recovery | Over temp: de-rate to 75% then 50%, auto-recovery | Input OVP: 320~370VAC on I-Type only, auto-recovery; withstand 440VAC for 48h
Current Ripple / Tolerance<5.0% @ rated current | Current accuracy ±5%
Operating / Storage TempTcase=-40C to +85C (refer to derating curve) | Storage -40C~+80C | Temp coefficient ±0.03%/C (0~60C)
Vibration / Humidity10~500Hz, 5G, 12min/cycle, X/Y/Z 72min each | 20~95% RH non-condensing
Isolation3.75KVac I/P-O/P, 2KVac I/P-FG, 1.5KVac O/P-FG
EMC Emission / ImmunityEN55015/CISPR15, GB/T17743; Harmonic Class C (@load>=50%); EN61000-3-3 | Immunity: EN61000-4-2 Level 3, EN61000-4-3 Level 3, EN61000-4-4 Level 3, EN61000-4-5 (6KV line-earth / 4KV line-line), EN61000-4-6 Level 3, EN61000-4-8 Level 4, EN61000-4-11, EN61547
Lifetime / MTBF / Size>50,000 hours at Tcase<75C | 2352.4K hrs (Telcordia SR-332) / 207.3K hrs (MIL-HDBK-217F, 25C) | 105 x 63 x 30mm | 0.42Kg

Safety Standards & Certifications

Safety StandardsUL8750 (Type HL, H-Type only), CSA C22.2 No. 250.13-12, ENEC AS/NZS IEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC Input 176-280Vdc, except L-Type), AS/NZS BS EN/EN61347-2-13, BS EN/EN62384, GB/T19510.1, GB/T19510.213, EAC TP TC 004, IS 15885(Part 2/Sec13) (I-Type only) | IP67
DALI StandardIEC 62386-101, 102, 207, 251; Device Type 6 (DT6)
Withstand VoltageI/P-O/P: 3.75KVAC | I/P-FG: 2.0KVAC | O/P-FG: 1.5KVAC
Insulation ResistanceI/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25C / 70% RH
EMC EmissionsBS EN/EN55015 (CISPR15), GB/T17743; Harmonic BS EN/EN61000-3-2 Class C (@load>=50%); BS EN/EN61000-3-3
EMC ImmunityBS EN/EN61547, BS EN/EN61000-4-2 Level 3, BS EN/EN61000-4-3 Level 3, BS EN/EN61000-4-4 Level 3, BS EN/EN61000-4-5 (6KV line-earth / 4KV line-line), BS EN/EN61000-4-6 Level 3, BS EN/EN61000-4-8 Level 4, BS EN/EN61000-4-11

Key Features

50W Constant Power with DALI-2 Dimming
XLG-50-DA2 delivers 50W constant power with L-Type (700mA / 60~142V) and H-Type (1050mA / 27~56V) options. Built-in DALI-2 DT6 interface provides isolated digital dimming down to ~8% brightness.
4 Version Types -- L / H / I-L / I-H
Choose L-Type for high-voltage LED strings or H-Type for low-voltage high-current loads. I-Type variants add input over-voltage protection (320~370VAC) and IS 15885 for India.
Class 2 + Type HL + IP67
Class 2 power limits simplify wiring. H-Type carries UL8750 Type HL for hazardous location lighting. Sealed metal housing supports indoor and outdoor use from -40C to +85C Tcase.
Active PFC + Global Certifications
PF>=0.97 at 115V and THD<10% at typical loads. UL/CSA/ENEC/AS/NZS/GB/EAC certifications enable worldwide deployment; IS 15885 for India on I-Type.
High Surge & Input OVP Option
Surge immunity 6KV line-to-earth / 4KV line-to-line. I-Type includes 320~370VAC input OVP and withstands 440VAC for 48 hours.
5-Year Warranty + Low Standby Power
Backed by a 5-year warranty. No-load/standby power below 0.5W on standard versions, meeting modern ErP requirements. Compact 105 x 63 x 30mm metal housing.

Frequently Asked Questions

What is the difference between L-Type and H-Type in XLG-50-DA2?

L-Type is optimized for high-voltage LED strings with a default current of 700mA and CC region of 60~142V. H-Type is optimized for lower-voltage, higher-current LED loads with a default current of 1050mA and CC region of 27~56V. Both deliver 50W constant power and support DALI-2 dimming.

Does XLG-50-DA2 support DALI-2 dimming?

Yes, all DA2 versions comply with IEC 62386-101, 102, 207, 251 and support Device Type 6 (DT6) DALI-2 digital dimming. The dimming circuit is isolated from the output. Minimum dimming level is approximately 8%.

What is the difference between standard and I-Type versions?

Standard L-DA2 and H-DA2 are global versions. I-L-DA2 and I-H-DA2 are India-market versions that add input over-voltage protection (320~370VAC) and IS 15885 certification. I-Type has slightly higher no-load power (<0.75W).

Is XLG-50-DA2 a constant-voltage driver?

No. XLG-50-DA2 is a constant-power LED driver that operates in constant-current mode within the stated CC region. It is designed for direct LED string connection, not for LED modules that require a constant-voltage supply.

What does Class 2 and Type HL certification mean?

Class 2 means the output is limited to a safe power level, simplifying wiring requirements. Type HL means the driver is UL8750 listed for use in Class I, Division 2 hazardous location lighting fixtures when installed per manufacturer instructions. Type HL applies to H-Type only.

Related Products

Explore individual models in the XLG-50-DA2 family.

Available Models

  • XLG-50-L-DA2 - 50W / 700mA / CC region 60 ~ 142V / 300~700mA adjustable / DALI-2 / IP67
  • XLG-50I-L-DA2 - 50W / 700mA / CC region 60 ~ 142V / 300~700mA adjustable / DALI-2 / IP67
  • XLG-50-H-DA2 - 50W / 1050mA / CC region 27 ~ 56V / 500~1400mA adjustable / DALI-2 / IP67
  • XLG-50I-H-DA2 - 50W / 1050mA / CC region 27 ~ 56V / 500~1400mA adjustable / DALI-2 / IP67
  • +8615397378162Scan to chat on WhatsApp
  • Inquiry
  • Back to Top

INQUIRY US

CATEGORIES

CONTACT US

Mobile:+8615397378162

Tel:+86-577-89887719

Whatsapp:+8615397378162

Email:info@ledluxhub.com

Add:ADD:NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA

OTHER LINK