105 x 63 x 30mm Metal Housing | 90~305VAC Universal Input (127~431VDC) | L-Type 700mA / H-Type 1050mA | Constant Power 50W | Class 2 | Active PFC | Type HL (except L-Type) | IP67 | DALI-2 DT6 | >50,000hrs | 5-Year Warranty
The MEAN WELL XLG-50-DA2 series is a 50W AC-to-DC constant-power LED driver family with DALI-2 digital dimming, IP67 protection, Class 2 power rating, and Type HL certification for Class I, Division 2 hazardous location lighting (H-Type only). It is designed for LED street lighting, architectural lighting, bay lighting, flood lighting, stage lighting, sports lighting, and industrial lighting.
It accepts universal 90~305VAC input (127~431VDC) and provides a constant-power 50W output. Two output types are available: L-Type with default current 700mA and CC region 60~142V, and H-Type with default current 1050mA and CC region 27~56V. Output current can be adjusted via an internal potentiometer (300~700mA for L-Type, 500~1400mA for H-Type). With peak efficiency up to 90%, the driver uses a fanless design and operates at case temperatures from -40C to +85C under free air convection.
The metal enclosure carries an IP67 rating for both indoor and outdoor use. All DA2 versions support IEC 62386 DALI-2 DT6 digital dimming down to approximately 8% minimum brightness, with isolated dimming circuitry. India versions (XLG-50I-L-DA2 / XLG-50I-H-DA2) add input over-voltage protection at 320~370VAC and comply with IS 15885. No-load / standby power consumption is below 0.5W.
Protection includes short-circuit (hiccup or constant current limiting), over-temperature (de-rate to 75% then 50%, auto-recovery), and input over-voltage (320~370VAC on I-Type only, auto-recovery; withstand 440VAC for 48h). The driver complies with global lighting safety and EMC standards including UL8750 Type HL, CSA, ENEC, AS/NZS, BS EN/EN, GB/T, EAC, and IS 15885 (I-Type only), and is backed by a 5-year warranty. Note: a switch must be installed between the mains and the LED driver to meet the latest ErP regulations.
Output ratings for the XLG-50-DA2 series. All values measured at 230VAC, rated current, 25C unless noted.
| Model | Default Current | CC Region | Full Power Current | Open Circuit Max | Adjustment Range | IP |
|---|---|---|---|---|---|---|
| XLG-50-L-DA2 | 700mA | 60 ~ 142V | 350~700mA | 160V | 300~700mA | IP67 |
| XLG-50I-L-DA2 | 700mA | 60 ~ 142V | 350~700mA | 160V | 300~700mA | IP67 |
| XLG-50-H-DA2 | 1050mA | 27 ~ 56V | 900~1400mA | 60V | 500~1400mA | IP67 |
| XLG-50I-H-DA2 | 1050mA | 27 ~ 56V | 900~1400mA | 60V | 500~1400mA | IP67 |
| Type | IP | Output Adjustment | Dimming | Input OVP | Notes |
|---|---|---|---|---|---|
| L-DA2 | IP67 | 300~700mA via built-in potentiometer | DALI-2 DT6 (isolated, down to ~8%) | No | 50W / 60~142V / 700mA default; Class 2 (except L-Type) |
| H-DA2 | IP67 | 500~1400mA via built-in potentiometer | DALI-2 DT6 (isolated, down to ~8%) | No | 50W / 27~56V / 1050mA default; Type HL |
| I-L-DA2 | IP67 | Same as L-DA2 | Same as L-DA2 | Yes (320~370VAC) | India version; withstand 440VAC for 48h; IS 15885 |
| I-H-DA2 | IP67 | Same as H-DA2 | Same as H-DA2 | Yes (320~370VAC) | India version; withstand 440VAC for 48h; IS 15885 |
| Input Voltage Range | 90~305VAC | 127~431VDC | 47~63Hz |
| Active PFC / THD / AC Current | PF>=0.97/115V, >=0.95/230V, >=0.92/277V at full load | THD<10% (@load>=50%/115VAC,230VAC; @load>=75%/277VAC) | 0.57A/115V, 0.29A/230V, 0.24A/277VAC |
| Inrush / Leakage / Breaker | Cold start 50A (twidth=350us measured at 50% Ipeak) / 230VAC per NEMA 410 | 16A breaker: 7 units (B type) / 12 units (C type) at 230VAC | <0.75mA/277VAC |
| Set Up / Rise Time | 500ms / 230VAC; 1200ms / 115VAC (DALI-2 startup timing tested with DALI controller supporting power-on function) |
| No-Load / Standby Power | Standard: <0.5W | I-Type: no-load <0.75W |
| Protection | Short circuit: hiccup or constant current limiting, auto-recovery | Over temp: de-rate to 75% then 50%, auto-recovery | Input OVP: 320~370VAC on I-Type only, auto-recovery; withstand 440VAC for 48h |
| Current Ripple / Tolerance | <5.0% @ rated current | Current accuracy ±5% |
| Operating / Storage Temp | Tcase=-40C to +85C (refer to derating curve) | Storage -40C~+80C | Temp coefficient ±0.03%/C (0~60C) |
| Vibration / Humidity | 10~500Hz, 5G, 12min/cycle, X/Y/Z 72min each | 20~95% RH non-condensing |
| Isolation | 3.75KVac I/P-O/P, 2KVac I/P-FG, 1.5KVac O/P-FG |
| EMC Emission / Immunity | EN55015/CISPR15, GB/T17743; Harmonic Class C (@load>=50%); EN61000-3-3 | Immunity: EN61000-4-2 Level 3, EN61000-4-3 Level 3, EN61000-4-4 Level 3, EN61000-4-5 (6KV line-earth / 4KV line-line), EN61000-4-6 Level 3, EN61000-4-8 Level 4, EN61000-4-11, EN61547 |
| Lifetime / MTBF / Size | >50,000 hours at Tcase<75C | 2352.4K hrs (Telcordia SR-332) / 207.3K hrs (MIL-HDBK-217F, 25C) | 105 x 63 x 30mm | 0.42Kg |
| Safety Standards | UL8750 (Type HL, H-Type only), CSA C22.2 No. 250.13-12, ENEC AS/NZS IEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC Input 176-280Vdc, except L-Type), AS/NZS BS EN/EN61347-2-13, BS EN/EN62384, GB/T19510.1, GB/T19510.213, EAC TP TC 004, IS 15885(Part 2/Sec13) (I-Type only) | IP67 |
| DALI Standard | IEC 62386-101, 102, 207, 251; Device Type 6 (DT6) |
| Withstand Voltage | I/P-O/P: 3.75KVAC | I/P-FG: 2.0KVAC | O/P-FG: 1.5KVAC |
| Insulation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25C / 70% RH |
| EMC Emissions | BS EN/EN55015 (CISPR15), GB/T17743; Harmonic BS EN/EN61000-3-2 Class C (@load>=50%); BS EN/EN61000-3-3 |
| EMC Immunity | BS EN/EN61547, BS EN/EN61000-4-2 Level 3, BS EN/EN61000-4-3 Level 3, BS EN/EN61000-4-4 Level 3, BS EN/EN61000-4-5 (6KV line-earth / 4KV line-line), BS EN/EN61000-4-6 Level 3, BS EN/EN61000-4-8 Level 4, BS EN/EN61000-4-11 |
L-Type is optimized for high-voltage LED strings with a default current of 700mA and CC region of 60~142V. H-Type is optimized for lower-voltage, higher-current LED loads with a default current of 1050mA and CC region of 27~56V. Both deliver 50W constant power and support DALI-2 dimming.
Yes, all DA2 versions comply with IEC 62386-101, 102, 207, 251 and support Device Type 6 (DT6) DALI-2 digital dimming. The dimming circuit is isolated from the output. Minimum dimming level is approximately 8%.
Standard L-DA2 and H-DA2 are global versions. I-L-DA2 and I-H-DA2 are India-market versions that add input over-voltage protection (320~370VAC) and IS 15885 certification. I-Type has slightly higher no-load power (<0.75W).
No. XLG-50-DA2 is a constant-power LED driver that operates in constant-current mode within the stated CC region. It is designed for direct LED string connection, not for LED modules that require a constant-voltage supply.
Class 2 means the output is limited to a safe power level, simplifying wiring requirements. Type HL means the driver is UL8750 listed for use in Class I, Division 2 hazardous location lighting fixtures when installed per manufacturer instructions. Type HL applies to H-Type only.